DifferentiAl Pressure (∆P) trAnsDuCer

Differential Pressure (∆P)

Transducer Installation

When ordered as part of a meter system with a LCR-II,

Liquid Control’s ∆P transducer is wired to the LCR-II

at the factory. The ∆P transducer can also be ordered

separately and installed onto a meter system already in

service. Refer to the ∆P transducer manual for complete

installation instructions. Instructions for wiring the ∆P

transducer to the LCR-II are provided on this page.

The ∆P Transducer requires an additional board (PN

81944) that mounts directly to the LCR-II CPU board.

Typically, a ∆P transducer operates in conjuction with a

shutdown device, such as a valve or a dead-man. The

shutdown control must be wired to the LCR-II and should

draw no more than 1 A.

to wire ∆P transducer to the lCr-ii:

1. Unplug the j1, j2, and j3 terminal blocks from the LCR-II

CPU board. Leave the wires in the terminals.

2. Remove the screw at the top left corner of the LCR-II

CPU board.

3. Plug the 81944 board into the J1 connectors on the LCR-

II CPU board.

4. Fasten the top left side of both boards to the housing with

the screw provided.

5. Plug terminal block j1 into the 81944 board. Plug j2 and

j3 back into the LCR-II CPU board

6. Plug terminal J16 into the 81944 board.
7. Route the ∆P transducer cable through a cable gland in

a port on the back of the LCR-II. Secure the cable gland.

LC recommends running the cable through weatherproof

conduit.

8. Connect the four ∆P transducer wires to terminals j3 on

the LCR-II CPU board and J16 on the 81944 board.

• Black to j3 terminal 46

• White to j3 terminal 51

• Yellow to j16 terminal 57

• Blue to j16 terminal 58

• Red to j16 terminal 59

9. Run the red jumper wire (provided with the ∆P transducer

kit) from the j8 terminal 32 to j16 terminal 59 (+5 V).

10. Route a two wire cable from the shutdown control device

through a cable gland in a port on the back of the LCR-II.

Secure the cable gland. LC recommends running the

cable through weatherproof conduit.

11. Connect the two wires from the shutdown control device

to terminal block j13, terminals 14 and 15.

11

12

13

PRINTER

SERIAL 485

TERMINAL

POWER

COUNTER

MH1

CTS RXD TXD RTS

GND

GND

485+A

485-B

CTS RXD TXD RTS +VP

EARTH

GND

GND

IN 1

IN 2

IN 3

IN 4

+5V OUT

+VP

GND

+12-24V

MH4

J20

J6

J3

J2

J1

J7

J7

C2

24

25

∆P Transducer

+5V(Out)/Jumper (59 to 32)

A/Blue (58)

+5V/Red (59)

B/Yellow (57)

GND/White (51)

+VP/Black (46)

B

Dead-Man

Shutdown

Auxiliary

Device

84040 Board

+Vo

Out7

The shutdown device should

draw no more than 1A.

When removing the J1

or J16 terminal from

the 81944 board, hold

down the right end of

the main CPU board to

prevent flexing.

Be Careful with the

CPU Board