environmental sealing Guidelines

The LCR-II includes sensitive electronic components, including a micro-controller that can be damaged by the

presence of moisture. Therefore, it is essential that all conduit ports, the cover, and the shaft seals be adequately

sealed by the installer to ensure watertight integrity. The conformal coating on the board and a moisture-absorbing

desiccant inside the enclosure mitigates the problem of corrosion due to moisture, but these measures only protect

the board from small amounts of moisture trapped inside the enclosure when the lid is closed in humid conditions.

They are not capable of protecting the unit over time if a continuous leak is present in the enclosure.

1.

Conduit Entrances

The LCR-II housing has seven conduit entrances, five ½" NPT female threads and two ¾" NPT. Use only ½" or ¾" NPT male

threaded fittings on the conduit entrances. Pressed in Caplugs and straight (rather than tapered) threads are inadequate as

seals for these entrances. Acceptable fittings are either metal or plastic conduit, pipe plugs, or cable glands. Threads should

be treated with PTFE-based “pipe dope” or a minimum of two revolutions of PTFE tape prior to installation. Threads should be

engaged a minimum of four full turns. When using cable glands, be sure the gland is sized properly for the outside diameter

of the cable and the elastometric seal around the cable sheath is compressed onto the cable. Use only one cable per cable

gland unless the gland is designed for multiple cables. When using conduit or Liquid-Tite, make sure that the opposite end is

connected to an environmentally sealed device. If the conduit is not sealed at the other device, fill the interior of the conduit at

the LCR-II with a silicone rubber sealant, such as RTV, to prevent moisture from running down the conduit into the enclosure.

2.

Cover Seals

To seal the LCR-II cover properly, ensure that the O-ring surrounding the cover is fit snug inside the groove, and tighten the

cover screw securely.

3.

Shaft Seals

Units with internal pulsers have an O-ring around the pulse encoder drive shaft that extends through the bottom of the LCR

housing. If a drive shaft adapter was attached at installation, make sure the O-ring around the shaft is securely seated in the

counter bore of the casting, covered with the flat washer provided, and held in place with the cotter pin provided. The control

switch on the front of the LCR-II is also sealed with an O-ring and held in place by a bushing secured with three socket head

cap screws. When replacing a control switch in the field, make sure the O-ring is in place on the switch shaft before reinstalling

the switch bushing.

Close and seal the Unit

Once the unit has been setup and tested, finish the installation by closing and sealing the housing. The LCR-II must

be environmentally sealed to protect the electronics against the elements. The LCR-II must also be sealed by a

Weights & Measures representative to guarantee the register is operating at the proper regulatory standards.

1. Secure the cables behind the LCR-II and the cables in the cab with cable ties.
2. If conduit was used during the installation, fill the conduit end inside the LCR-II with silicon RTV (provided with shipment, PN

82575).

Read and follow the directions of the Environmental Sealing Guidelines below.

3. Tighten the cover bolt using a large flat-tip screwdriver or a 7/16” socket. Completely close the gap between the cover and the

housing tab.

Read and follow the directions of the Environmental Sealing Guidelines below.

4. Seal the cover bolt and the switch plate bolts with a wire/lead seal.

See Weights & Measures Seals on pg. 33.

After the LCR-II is powered correctly, continue on to the LectroCount LCR-II Setup and Operation manual to setup the LCR-II for

operation. You will want to setup and test the LCR-II before closing and sealing the unit.

IMPorTanT: before sealing the lCr-II

Any water or moisture damage to the LCR-II as result of improper sealing will not be covered under the product warranty.

Sealing the LCR-II is the Responsibility of the Installer

PosT InsTallaTIon