Transmission Service Procedure

Inline Exchange

Warning:

It is not necessary to empty the waste tank before beginning an exchange. If beginning an ex-

change with fluid in the waste tank ensure that there is less fluid in the clean tank than the remaining capacity
of the waste tank. Failure to do so will result in waste tank overflowing!

Connection to Vehicle using H-Adapter

1. Connect appropriate adapters to vehicle transmission cooler lines. Attach opposite ends to H-adapter.

Ensure valve is partially open.

2. Start the vehicle.

3. Determine ATF flow direction then fully open H-adapter valve.

4. With the male to male couplers connected to the TransTech IV hoses, attach the INLINE RETURN hose

to the transmission output side of the H-adapter. Attach CLEAN FLUID hose to the transmission return
side of the H-adapter valve.

5. Close valve on H-Adapter.

7