Error alerts – MotorVac TRANSTECH IV User Manual

Page 18

Advertising
background image

[email protected] www.motorvac.com

Error Alerts

The TransTech IV has been designed to stop the service and alert the operator in certain instances if the unit
is not functioning properly. There are 2 different notifications, one that occurs while draining and the other
while the unit is filling. See below for details.

Fig.1

Alert

Notification

Cause

Hardware
Troubleshooting
steps

Recovery


Fill
Error

see
Fig. 1


The alarm sounds.

The following LEDs
flash: INLINE,
DIPSTICK, MANUAL
FILL.


There is a hardware or
software problem that
has caused the unit
to lose track of how
much fluid is in the
Clean Tank.

This alert prevents
the unit from overfill-
ing the transmission if
there is a problem with
the fluid level sensing
system.


Empty the Clean ATF
tank on the TransTech
IV before attempting
another exchange.

Note: Do not leave oil
standing above the 0
line of the clean tank
for extended periods
of time. This may
cause the unit to lose
track of fluid levels.


Press STOP button to
silence the buzzer.
Due to the probability
of an overfill condition,
the unit cannot recover
from this error.
Reset the unit to at-
tempt further opera-
tion.

15

Advertising