Before You Begin

First Time Operation

NOTE

The following process is used to flush factory testing fluids out
of your new machine, and is only necessary before the first
time you use the unit.

Remember to send in your warranty card to properly register
your machine.



1.

Verify that the unit’s

fuel filter is connected and securely in place on the filter base assembly at the rear of

the cabinet

.


2.

Check the output/return hoses, battery connections, and all external components for damage

.


3.
Turn

the

Pressure Adjust regulator on the unit control panel counterclockwise until it is completely

open.


4.

Attach the unit to a motor vehicle battery by connecting the red battery clip to the positive (+) battery
terminal and connect the black battery clip to a solid ground point as far from the battery as possible.


5.

Fill the unit’s reservoir with

clean gasoline

until the

Fuel Level Window

indicates 1/4 tank

.

6.

Connect the unit’s output (red) hose and return (black) hose together by using the

#060-1100 and #060-1400 adaptors and securing them with a clamp. Follow the procedures below to
flush fuel through the system:

• Press and hold the Start button for five minutes. This will thoroughly flush the system with clean

gasoline.

• Release the Start button.

7.

Disconnect the output and return lines.


8.

Connect the #060-1100 adaptor to the (red) output hose. To flush the gasoline from the unit’s

reservoir

using the following procedure:
• Direct the adaptor on the (red) output hose into an appropriate container.
• Press and hold the Start button until the unit’s reservoir is empty.
• Release the Start button.

Dispose of the fuel in an environmentally approved method.