8 a 7 b 8 b 7 a – Dixon Valve 100 TON RAM SEC06 External Swaged Ground Joint User Manual

Page 5

Advertising
background image

100 Ton Ram Instruction Manual

Boss Ground Joint Holedall Couplings

customer service

800

355

1991

3

Section 6

Lubricate the outside of the ferrule with Crisco

®

(recommended) or high viscosity oil or heavy duty
grease.

Lubricate the I.D. of both die halves with Crisco

®

(recommended) or high viscosity oil or heavy duty
grease.

Lifting up the hose, insert one die half under the
hose. Lower the hose so that it rests on the die.
Insert the other die half. Make sure that the seams
of the die do not line up with the seams on the die
holders.

While holding the die in place with one hand, place
one of the tie down bars over the die so that it does
not come out of the die holder unexpectedly.
Secure the tie down bar by tightening the bolt.

8a

7b

8b

7a