Max Displayed Range (Unit Only):

Fuel Flow:

199.9 Gals/Hr or 162.0 br Gal/Hr or 1199 Lbs/Hr or 749 Ltr/Hr.

Fuel Remaining:

999 Gals. or 811 br Gal. or 1999 Lbs. or 1999 Ltr.

Fuel Used:

999 Gals. or 811 br Gal. or 1999 Lbs. or 1999 Ltr.

Time to Empty:

19 hours 59 minutes

AUX:

+/- 1999

RS-232/422 Input Ports (FP-5L Only):

Single Line Receive Method:

RS-232C or RS-423

Dual Line Receive Method:

RS-422 or RS-485 (with 120 ohm external resistor)

Protocol:

1 Start bit, 8 Data bits, 1 Stop bit.

Baud Rate:

1200, 4800, 9600

Receive Format:

Moving Map, Northstar or NEMA.

RS-232/422 Output Port (FP-5L Only):

Transmit Method:

RS-232C Single Line.

Protocol:

1 Start bit, 8 Data bits, 1 Stop bit.

Baud Rate:

9600 (Receive Format must be set to Moving Map).

Transmit Format:

King KLN88, Garmin, or UPS.

Fuel Flow Transducer, Standard (FT-60):

Range:

0.6 to 60 GPH

Linearity:

2% (8 to 60 GPH)

K Factor:

Approx. 80,000

Pressure Drop:

1.2 PSI at 30 GPH
4.8 PSI at 60 GPH

Working Press:

200 PSI

Min. Burst Press: 2000 PSI
Temp. Range:

-65'C to 125'C

Fuel Ports:

1/4" Female NPT

Fuel Flow Transducer, Special (FT-90):

Range:

3 to 90 GPH

K Factor:

Approx. 19,500

Pressure Drop:

.31 PSI at 30 GPH
2.8 PSI at 90 GPH

Working Press:

200 PSI

Min. Burst Press: 2000 PSI
Temp. Range:

-65'C to 125'C

Fuel Ports:

1/4" Female NPT

Fuel Pressure Transducer (PT-100GA):

Range:

0 to 100 PSI

Over Press:

300 PSI without damage.

Min. Burst Press: 500 PSI
Temp. Range:

-40'C to 125'C

Material:

303 Stainless Steel

Press. Port:

1/4" Male NPT

Fuel Flow Transducer, Special (FT-180):

Range:

3.6 to 180 GPH

K Factor:

Approx. 48,000

Pressure Drop:

1.78 PSI at 120 GPH

Working Press:

3000 PSI

Temp. Range:

-450'F to 300'F

Fuel Ports:

1/2" AN Male w/37' flare