Max Displayed Range (Unit Only):
Fuel Flow:
199.9 Gals/Hr or 162.0 br Gal/Hr or 1199 Lbs/Hr or 749 Ltr/Hr.
Fuel Remaining:
999 Gals. or 811 br Gal. or 1999 Lbs. or 1999 Ltr.
Fuel Used:
999 Gals. or 811 br Gal. or 1999 Lbs. or 1999 Ltr.
Time to Empty:
19 hours 59 minutes
AUX:
+/- 1999
RS-232/422 Input Ports (FP-5L Only):
Single Line Receive Method:
RS-232C or RS-423
Dual Line Receive Method:
RS-422 or RS-485 (with 120 ohm external resistor)
Protocol:
1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate:
1200, 4800, 9600
Receive Format:
Moving Map, Northstar or NEMA.
RS-232/422 Output Port (FP-5L Only):
Transmit Method:
RS-232C Single Line.
Protocol:
1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate:
9600 (Receive Format must be set to Moving Map).
Transmit Format:
King KLN88, Garmin, or UPS.
Fuel Flow Transducer, Standard (FT-60):
Range:
0.6 to 60 GPH
Linearity:
2% (8 to 60 GPH)
K Factor:
Approx. 80,000
Pressure Drop:
1.2 PSI at 30 GPH
4.8 PSI at 60 GPH
Working Press:
200 PSI
Min. Burst Press: 2000 PSI
Temp. Range:
-65'C to 125'C
Fuel Ports:
1/4" Female NPT
Fuel Flow Transducer, Special (FT-90):
Range:
3 to 90 GPH
K Factor:
Approx. 19,500
Pressure Drop:
.31 PSI at 30 GPH
2.8 PSI at 90 GPH
Working Press:
200 PSI
Min. Burst Press: 2000 PSI
Temp. Range:
-65'C to 125'C
Fuel Ports:
1/4" Female NPT
Fuel Pressure Transducer (PT-100GA):
Range:
0 to 100 PSI
Over Press:
300 PSI without damage.
Min. Burst Press: 500 PSI
Temp. Range:
-40'C to 125'C
Material:
303 Stainless Steel
Press. Port:
1/4" Male NPT
Fuel Flow Transducer, Special (FT-180):
Range:
3.6 to 180 GPH
K Factor:
Approx. 48,000
Pressure Drop:
1.78 PSI at 120 GPH
Working Press:
3000 PSI
Temp. Range:
-450'F to 300'F
Fuel Ports:
1/2" AN Male w/37' flare
16