Shooting

Setting Area Analysis Parameters

This section explains how to apply area analysis tools to the
thermal image.

1

Make sure that the thermal camera is in
null mode (see p. 14).

Press the

MENU/ENTER button to open the Main
Menu.

2

Use the UP or DOWN arrow to navigate to
the Analysis line. Then press the
MENU/ENTER button to open the Analysis
menu.





3

Use the UP or DOWN arrow
to navigate to the Area line.

Then press the

MENU/ENTER button to open
the Area submenu.

4


Setting the analysis area.

• Press the UP or DOWN arrow to select one

or more areas, then press the MENU/
ENTER
button. A check mark will appear to
the left of the selected area(s) and one or
more boxes will appear on the screen.

• A reading in a box with a label at its left will

appear at the top right corner. The reading
represents the highest/lowest/average
temperature of the current area.

• Press the LEFT or RIGHT arrow to select

the maximum, minimum or average
temperature for display. The letter in the
label to the left of the box indicates which
temperature is displayed: H for the highest
temperature, L for the lowest, and A for the
average.