Initial setup, Contd, Adding vacuum pump oil – Robinair 34134Z Refrigerant Recovery, Recycle, Recharge Unit User Manual

Page 10

Advertising
background image

©

2003 SPX Corporation

8

NOTE:

At this time, the unit is also automatically evacuating all air from the unit.

7. With the vacuum pump running, slowly add oil until the level rises to the

center of the oil sight glass.

8. When the vacuum pump countdown reaches zero, the vacuum pump will

stop and the unit display will change to the recover function.

9. Replace the plastic plug in the oil fill port.

After adding oil to the vacuum pump, add refrigerant to the internal storage
vessel. Refer to the instructions on the next page.

Note: The unit’s
weight default is in
pounds. To change
to kilograms:
1. Press the

Up

and

Down

arrow keys

at the same time.

will be displayed.

2. Press the

Up

or

Down

arrow key

to toggle to KG.

3. Press

Mode

key

until display reads
EXIT.

UNITS LBS

Initial Setup

Adding Vacuum Pump Oil

contd.