Step 3 - inspection tool function check – IDEC DATAVS1 Series User Manual

Page 25

Advertising
background image

Instruction Manual

SVS1 Series

20

5.6.

Step 3 - Inspection tool function check


In Monitor Mode, it is possible to check that the inspection tool settings entered during the
configuration step function correctly. The user can choose from five different monitoring modes. The
chart below provides a description of the main features of the five available modes with instructions on
how to enable viewing.

Mode

Example

Enable

Description

Camera
Mode

ARROW DOWN

The monitor displays the sensor field
focus in full screen mode. No type of
information is indicated regarding
inspection results.

Monitor
Mode

ARROW UP

The monitor displays the sensor field
focus in full screen mode. The following
information is also displayed:

• Current control status (top right hand

corner)

• ROI

• Inspection result (bottom left hand

corner)

Fail
Mode

LEFT ARROW

The monitor displays the image of the
last inspection which had negative (fail)
result (fault)

Zoom
Mode

RIGHT ARROW

An image of the sensor field focus is
displayed on the monitor with 200% zoom.
A rectangle in the bottom right-hand corner
indicates the position of the displayed area
compared to the overall image and the
ROI position. To move the zoom area, use
the ARROW buttons. Press ESC to exit
zoom mode.

Statistics

SET BUTTON

Statistics on the inspection results are
displayed on the monitor. The
information displayed include:

• Inspection

result

Current inspection outcome

• Score

Current inspection result

• Average

score

Average calculated score

• Score

MIN-MAX

Minimum and maximum calculated
score

• Execution time (ms)

Total inspection execution time

• Average execution time (ms)

Average total inspection execution
time

• Measurement

count

Number of inspections executed

Advertising