Step 3 - inspection tool function check – IDEC DATAVS1 Series User Manual
Page 25
Instruction Manual
SVS1 Series
20
5.6.
Step 3 - Inspection tool function check
In Monitor Mode, it is possible to check that the inspection tool settings entered during the
configuration step function correctly. The user can choose from five different monitoring modes. The
chart below provides a description of the main features of the five available modes with instructions on
how to enable viewing.
Mode
Example
Enable
Description
Camera
Mode
ARROW DOWN
The monitor displays the sensor field
focus in full screen mode. No type of
information is indicated regarding
inspection results.
Monitor
Mode
ARROW UP
The monitor displays the sensor field
focus in full screen mode. The following
information is also displayed:
• Current control status (top right hand
corner)
• ROI
• Inspection result (bottom left hand
corner)
Fail
Mode
LEFT ARROW
The monitor displays the image of the
last inspection which had negative (fail)
result (fault)
Zoom
Mode
RIGHT ARROW
An image of the sensor field focus is
displayed on the monitor with 200% zoom.
A rectangle in the bottom right-hand corner
indicates the position of the displayed area
compared to the overall image and the
ROI position. To move the zoom area, use
the ARROW buttons. Press ESC to exit
zoom mode.
Statistics
SET BUTTON
Statistics on the inspection results are
displayed on the monitor. The
information displayed include:
• Inspection
result
Current inspection outcome
• Score
Current inspection result
• Average
score
Average calculated score
• Score
MIN-MAX
Minimum and maximum calculated
score
• Execution time (ms)
Total inspection execution time
• Average execution time (ms)
Average total inspection execution
time
• Measurement
count
Number of inspections executed