King Electric FCS13 heating cable repair kit User Manual

Important: save these instructions, Ab c d e

Advertising
background image

FCS 13 Repair Kit Installation Instruction

Installation, Operation and Maintenance Instructions

IMPORTANT: Save These Instructions!

WARNING: ELECTRIC SHOCK HAZARD

Disconnect all power before installing or servicing
the heating cable and accessories. FC heating
cable must be grounded properly in accordance
with the National Electrical Code (NEC). Failure to
comply can result in personal injury or property
damage. Only a qualified licensed electrical
contractor shall install and service of FC heating
cable and accessories, otherwise the warranty is
voided.

Note:·All electrical wiring, including Ground Fault
Circuit Interrupters (GFCI), must be done according
to the NEC and local codes by a qualified installer.

Description

The repair kit is for repairing heating cable that is damaged
during installation of the heating cable/mat. The kit includes
jumper wires to bridge the heating element after the damaged
section is removed. The kit contents are sufficient to repair one
damaged section up to 5 inches long. If more than 5 inches of
cable has been damaged, the mat must be replaced.

Tools Required

• Wire Strippers 16-26 AWG
• Gloves
• Scissors
• Crimp tool
• Heat gun
• Multimeter (capable of 200K ohms)

Item

Qty

Description

A

2

Jumper wires

B

6

Connectors

C

4

Small heat shrink tubing

D

1

Ground Wire (non-insulated)

E

1

Large heat shrink tubing

A

B

C

D

E

Rev 11.01.12

www.king-electric.com

1

Advertising