Port configuration for fc infusion, Port configuration for fc – Teledyne LeCroy SierraFC M164 User Manual User Manual

Page 272

Advertising
background image

Teledyne LeCroy

Port Configuration for FC InFusion

272

 

 

SierraFC M164 Protocol Analyzer User Manual

Port Configuration for FC InFusion

Select Configuration > Port Configuration or click the Port Configuration icon 

 to 

display the Set Port Configuration dialog, or press the yellow ‘P’ icon.

To record traffic both before and after the FC InFusion modifies (jams) it, select 
Analyzer/Jammer/Analyzer on the port that you want to jam. In the following figure, 
there is a match on Port 2.

Note:

In Analyzer/Jammer/Analyzer (AJA) port configuration the LEDs for ports 3 and 4 represent 

ports 1 and 2 post‐jam. The LEDs for ports 3 and 4 do not turn off when they are disconnected. 

Figure 4.6: Ports Configuration Dialog with Analyzer/FC InFusion/Analyzer Port Match

Note:

You can select only one Jammer port at a time when using the AJA configuration. 

To record traffic from other ports after the FC InFusion modifies (jams) them, select a 
combination of ports that have Jammer/Analyzer specified under them. The different 
configurations accommodate different possible user setups and requirements.

Note: To display the current Port Configuration, click Show Analyzer to go to the analyzer 
application, then click the green button in the lower right corner to display the 
Port Status window (see 

“Port Status” on page 202

).

Important Information for Jammer and Analyzer

Jammer intercepts and delays traffic on both directions simultaneously, so Originator 
sends to Jammer, Jammer delays and sends to Responder, Responder sends to Jammer, 
Jammer delays and sends to Originator. However, Jammer modifies traffic in one 
direction only: from Originator to Responder, or from Responder to Originator.