Port Configuration for FC InFusion
272
SierraFC M164 Protocol Analyzer User Manual
Port Configuration for FC InFusion
Select Configuration > Port Configuration or click the Port Configuration icon
to
display the Set Port Configuration dialog, or press the yellow ‘P’ icon.
To record traffic both before and after the FC InFusion modifies (jams) it, select
Analyzer/Jammer/Analyzer on the port that you want to jam. In the following figure,
there is a match on Port 2.
Note:
In Analyzer/Jammer/Analyzer (AJA) port configuration the LEDs for ports 3 and 4 represent
ports 1 and 2 post‐jam. The LEDs for ports 3 and 4 do not turn off when they are disconnected.
Figure 4.6: Ports Configuration Dialog with Analyzer/FC InFusion/Analyzer Port Match
Note:
You can select only one Jammer port at a time when using the AJA configuration.
To record traffic from other ports after the FC InFusion modifies (jams) them, select a
combination of ports that have Jammer/Analyzer specified under them. The different
configurations accommodate different possible user setups and requirements.
Note: To display the current Port Configuration, click Show Analyzer to go to the analyzer
application, then click the green button in the lower right corner to display the
Port Status window (see
Important Information for Jammer and Analyzer
Jammer intercepts and delays traffic on both directions simultaneously, so Originator
sends to Jammer, Jammer delays and sends to Responder, Responder sends to Jammer,
Jammer delays and sends to Originator. However, Jammer modifies traffic in one
direction only: from Originator to Responder, or from Responder to Originator.