1. Turn at least one (1) oven switch ON. The VFD display should show the POWER and RUN

LED lamps lit up, and a numeric value should appear in the window display.

The VFD controller is adjusted at the factory to the values displayed in the chart below.

Top Middle Bottom

Single

X

20 Hz

25 Hz

30Hz

X

20 Hz

25 Hz

30Hz

X

35 Hz

40 Hz

45 Hz

X

X

35 Hz

40 Hz

45 Hz

X

20 Hz

25 Hz

30Hz

X

30 Hz

35 Hz

40 Hz

X

40 Hz

45 Hz

50 Hz

X

X

30 Hz

35 Hz

40 Hz

X

X

40 Hz

45 Hz

50 Hz

X

X

40 Hz

45 Hz

50 Hz

X

X

X

45 Hz

50 Hz

55 Hz

Fire Suppression

60 Hz

Triple

Double

VFD Controller Settings

Switches On

1832, 1855 & 2440 3240, 3255 & 3270 3855 & 3870

Function

Store

VFD Controller Display

Window Display

If you require either more or less air flow, follow these steps:

Variable Frequency Drive Adjustments

AVI HOOD INITIAL START-UP

All AVI Hoods are functionally tested at the factory. Operation is verified, and adjust-

ments are made to ensure proper operation. However, field conditions are sometimes different
than factory conditions. These variables make it necessary to have an authorized service techni-
cian verify operation and make field adjustments if needed. The following items must be checked
and verified to meet the specifications and requirements stated in this manual prior to the hood be-
ing commissioned:

Correct fan rotation.

Balanced make-up air.

The Initial Start-Up Checklist must be completed at time of installation, signed by the Cus-

tomer and returned to XLT Ovens to initiate Warranty Policy.