Progressive International Electronics PIcon II Console User Manual

Page 43

Advertising
background image

PIcon II

Diagnostics

Rev 1.0

January 2014

38

Locate top diagnostic window displayed on terminal

Select D, Section Diagnostics

Select P, Printer Diagnostics

Select D, Download the Print Header.

At the prompt, download may be aborted by pressing Escape key or continued by

entering any other key.

If continuing download, C’s will continue to appear onscreen until the file to be

downloaded is selected. To select the print header file, go to Hyperterm’s toolbar and

select Transfer, then Send File. At the dialog box, browse for file to be downloaded.

Select the file you have previously written for the print header. Under the Protocol

section of the dialog box, select Xmodem. Press Send button. File will be downloaded.

When download is complete, program will automatically return to the previous prompt.

Configure Pump

Dispenser specific options must be selected for some dispenser brands. Follow the sequence

below to configure these brands. If C, Configure Pump, does not appear after selecting

Dispenser, this particular dispenser does not require configuration.

Locate top diagnostic window displayed on terminal

Select D, Section Diagnostics

Select D, Pump Diagnostics

Select P, Pump Diagnostics — If C, Configure Pump, does not appear at this point, this

particular dispenser does not allow configuration.

Select C, Configure Pump

Select from options in menu window