Troubleshooting, Caution – Lincoln Electric IM827 POWER FEED 10M WIRE FEEDER User Manual
Page 59

Display shows any of the following:
Err 020
An attempt was made to reprogram
a CB or feed head but the program
did not verify.
Check for potential electrical HF
noise generators in the area. Try
removing the noise source and pro-
gramming again. If the Err 020 still
occurs, either replace the EEPROM
chop(s) in teh board being
reprogammed or replace the whole
PC board being reprogrammed.
Err 100
The Power Source issued a shut
down command for some reason.
See what to Do on Err 006.
Err 200
No Heart beat response from the
PS.
See what to Do on Err 006.
Err 201
No Heart beat response from an
object.
If this occurs while welding, the sta-
tus LED should be flashing red on
the object that lost heart beat.
Otherwise, look for any nodes that
are flashing green. This indicates
they have not been recognized and
there is a power source problem
(see power source trouble shooting
section). If the status LED is either
flashing or solid red, there may be a
problem with continuity in the com-
munication lines. Check the lines for
continuity, in the cable and harness-
ing (refer to wiring diagram).
Err 210
EEPROM error.
Parameter recaled at power up was
out of range. Rotate encoder knob
to reset . Check all settings before
procedding to weld. If this condition
persists the replac the CB mother
PC board.
E-3
TROUbLESHOOTING
E-3
POWER FEED
®
10M SINGLE WIRE FEEDER
Observe all Safety Guidelines detailed throughout this manual
Error Codes for the Power Wave 455: Code 10555 and below
Note: For any Err # listed below write down the error number for refference and try cycling power to see if the
error clears itself. If not, refer to what the What to Do column for the given Err.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
PRObLEMS
(SYMPTOMS)
POSSIbLE
CAUSE
RECOMMENDED
COURSE OF ACTION