Enclosure – Detcon SmartWireless CX User Manual

Page 11

Advertising
background image

Sentinel CX

Sentinel CX Sensor Station IM

Rev. 1.4

Page 7 of 26

12V Battery Power

12V Return

Relay PCA

NC

COM

NO

FAULT

NC

COM

NO

ALARM 3

NC

COM

NO

ALARM 2

NC

COM

NO

ALARM 1

Enclosure

ALARM 2

(Gray) 3

Alarm Connector

ALARM 3

(Brown) 4

FAULT

(BLUE) 5

ALARM 1

(White) 2

GND

(Black) 1

1

1

2

3

4

5

Figure 6 External Alarm Connector pin out for ‘Wet’ alarm contacts

Sensor Connector Ratings

Voltage: 9-11.2 VDC
Current: 2 Amps max through single relay connector (2 Amps max total across 4 connectors.

CAUTION

When utilizing ‘Wet’ contacts, the maximum power that can be drawn by the
annunciators is 2A.

The SmartWireless® CX is also available with ‘Dry’ relay contacts (Figure 7). Dry relay Contacts allow
the user to control annunciators that operate off an exterior power source that relies on the controller to
provide only contact closure to apply voltage to the annunciator. The relays are rated for 120-220 VAC/24
VDC, 2 A max. It is important to note that the ‘Dry’ contact feature utilizes a common return for all
annunciators.

Relay PCA

NC

COM

NO

FAULT

NC

COM

NO

ALARM 3

NC

COM

NO

ALARM 2

NC

COM

NO

ALARM 1

Enclosure

ALARM 2

(Green) 3

Alarm Connector

(Pin 2 is not used)

ALARM 3

(Orange) 4

FAULT

(Blue) 6

ALARM 1

(White) 1

COM

(Black) 5

1

1

2

3

4

5

6

Figure 7 External Alarm Connector Pin out for ‘Dry’ alarm contacts

Advertising