Electric models only, Warning (gas models only), Term line voltage – American Dryer Corp. SL50 User Manual

Page 18: High

Advertising
background image

18

American Dryer Corp.

113403 - 14

Electric Models Only

All electrically heated dryers must be connected to the electric
service shown on the dryer’s data label. The connecting
wires must be properly sized to handle the rated current.

2/8/08

Warning (Gas Models Only)

Dryers built for use with a voltage between 200
and 240 must verify the input voltage during

installation. If the nominal voltage is outside of the

!

TERM

LINE VOLTAGE

50 Hz

60 Hz

HIGH

260
226

283
249

MED

239
208

260
230

LOW

217
189

236
208

medium tolerances shown on
the diagram below, adjust the
autotransformer, located near
the burner assembly. To adjust
the autotransformer wiring,
place the red wire on the
appropriate tap (HIGH, MED,
LOW) of the autotransformer.
For additional wiring details,
refer to the electrical diagram
located on the inside of the control panel.

Electrical Service Specifications
Gas and Steam Models Only

2/8/08

ELECTRICAL SERVICE SPECIFICATIONS

IMPORTANT:

NOTES: A.

B.


C.

208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

When fuses are used they must be dual element, time delay, current limiting, class RK1 or

RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National
Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others,
calculate/verify correct breaker size according to appliance amp draw rating and type
of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX. AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

SL20 Gas

120

2

8.9

15

200

2

7.7

7.8

15

208

2

7.6

15

220

2

7.4

15

230

2

7.3

15

240

2

7.2

7.0

15

SL31 Gas

120

2

10.3

15

200

2

8.7

8.8

15

208

2

8.4

15

220

2

8.1

8.1

15

230

2

7.4

15

240

2

7.7

7.0

15

SL31 Steam

120

2

9.3

15

208

2

6.0

15

220

2

5.5

15

230

2

5.4

15

240

2

5.1

15

SL50 Gas

120

2

15.6

20

200

2

10.5

20

208

2

10.5

20

220

2

10.0

10.7

20

230

2

10.8

20

240

2

9.7

20

SL50 Steam

120

2

14.4

20

200

2

8.2

20

208

2

8.2

20

220

2

7.8

8.4

20

230

2

8.5

20

240

2

7.6

20

SL75 Gas

120

2

15.6

20

200

2

10.5

20

208

2

10.5

20

220

2

10.0

10.7

20

230

2

10.8

20

240

2

9.7

20

SL75 Steam

120

2

14.4

20

200

2

8.2

20

208

2

8.2

20

220

2

7.8

8.4

20

230

2

8.5

20

240

2

7.6

20

ELECTRICAL SERVICE SPECIFICATIONS

IMPORTANT:

NOTES: A.

B.

C.

208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5
ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical
Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

OVEN

kW

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

SL20

200

2

5.6

32.7

32.7

45

208

2

4.1

24.2

35

208

2

6.1

34.0

45

220

2

6.8

35.6

45

230

2

5.0

26.4

35

230

2

7.4

36.8

50

240

2

5.4

27.1

35

240

2

8.1

38.4

38.4

50

208

3

6.5

22.7

30

240

3

7.5

22.6

30

380

4

6.8

15.0

20

400

4

7.5

15.5

20

416

4

8.1

15.8

20

SL31

200

2

12.5

68.4

67.7

90

208

2

7.9

43.8

60

208

2

13.5

70.7

90

230

2

8.3

41.3

60

230

2

12.4

59.1

80

240

2

9.0

42.7

60

240

2

13.5

61.5

80

208

3

13.5

43.3

60

220

3

11.3

35.3

50

230

3

12.4

36.5

50

240

3

13.5

37.7

50

380

4

11.3

22.8

22.6

40

400

4

12.4

23.1

40

416

4

13.5

23.7

40

SL50

200

2

14.8

82.1

110

208

2

16.0

85.1

110

220

2

13.4

68.8

69.4

90

230

2

14.7

72.3

100

240

2

16.0

74.2

75.1

100

200

3

14.8

51.0

70

208

3

16.0

52.6

70

220

3

13.4

43.0

43.6

60

230

3

14.7

45.3

60

240

3

16.0

46.0

60

380

4

13.4

28.0

28.6

40

400

4

14.8

29.8

40

416

4

16.0

30.7

40

SL50 Dual Voltage 480 / 120

120

2

0.0

13.2

15

480

3

16.0

19.2

25

SL50 Dual Voltage 480 / 240

240

2

0.0

6.5

15

480

3

16.0

19.2

25

SL50 Dual Voltage 600 / 120

120

2

0.0

13.2

15

600

3

16.0

15.4

20

SL50 Dual Voltage 600 / 240

240

2

0.0

6.5

15

600

3

16.0

15.4

20

SL75

200

2

20.3

109.8

150

208

2

22.0

113.9

150

220

2

18.5

91.7

92.3

125

230

2

20.3

96.3

125

240

2

22.0

99.2

125

208

3

22.0

69.2

90

220

3

18.5

56.2

56.8

80

230

3

20.3

59.1

80

240

3

22.0

60.4

80

380

4

18.5

35.6

45

380

4

18.5

36.2

50

400

4

20.3

37.8

50

416

4

22.0

39.1

50

Advertising