5 supported functions – KROHNE ALTOSONIC V Modbus EN User Manual

Page 10

Advertising
background image

ALTOSONIC V

ModBus Manual 0300 rev07 E

7.30855.35.00

Page 10 of 64

5 SUPPORTED FUNCTIONS

All data addresses in Modbus messages are referenced to zero.

For example:

Coil 1 is addressed as Coil 0000.

Holding register 40001 is addressed as 0000. Note that the function code specifies the operation of

a ‘holding register’, therefore the 4xxxx reference is implicit.

When functions which do not support broadcast requests, are accessed with a broadcast address, the

request will be rejected.

5.1

Function 01: READ COIL STATUS

Description

Function 1 reads the ON/OFF status of discrete inputs or discrete variables in the slave (0 x references

called coils).

Broadcast is not supported.


Query
The query specifies the starting coil and the quantity of coils to read.

The maximum number of coils requested each request is limited to 2000.

Example

Here is an example of a request to read coils 20-56 from slave device 17:

Starting address

Number of points

Header


--

Slave

Address

11(h)

Function


01(h)

Hi

00(h)

Low

13(h)

Hi

00(h)

Low

25(h)

Error check


--

Trailer


--

Response

Data

Header


--

Slave
address


11(h)

Function


01(h)

Byte
count


05(h)

Coil

27-20
CD(h)

Coil

35-28
6B(h)

Coil

43-36
B2(h)

Coil

51-44
0E(h)

Coil

56-52
1B(h)

Error check

--

Trailer

--

The coil status in the response message is packed as one coil per bit of the data field. Status is

indicated as 1= ON, 0= OFF.

The LSB of the first data byte contains the coil addressed in the query. The other coils follow toward

the high order end of this byte and from 'low order to high order' in subsequent bytes.

If the returned coil quantity is not a multiple of eight, the remaining bits in the final data byte will be

padded with zeros (toward the high order end of the byte). The Byte Count field specifies the quantity

of complete bytes of data.

The status of coils 27-20 is shown as the byte value CD hex, or binary 1100 1101.

Coil 27 is the MSB of this byte, and coil 20 is the LSB. Left to right, the status of coils 27 through 20 is

ON-ON-OFF-OFF-ON-ON-OFF-ON.

By convention, bits within a byte are shown with the MSB to the left, and the LSB to the right. Thus the

coils in the first byte are '27 through 20', from left to right, The next byte has coils '35 through 28', left to

right. As the bits are transmitted serially, they flow from LSB to MSB: 20…27, 28...35, and so on.

In the last data byte, the status of coils 56-52 is shown as the byte value 1B hex, or binary 0001 1011.

Coil 56 is in the fourth bit position from the left, and coil 52 is the LSB of this byte. The status of coils

56 through 52 is ON-ON-OFF-ON-ON.