71

B+RW

EXT: save changed data in float write field (EXT
222..225)

8

6

automatic reset

72

B+RW

EXT: restart proving of external flowmeter

8

6

automatic reset

73

B+RW

Batch 1 reset averages For Continuous Pipe Line
Measurement by host , not for the UFP internal CPL
batch mode

4

automatic reset

74

B+RW

Batch 2 reset averages

For Continuous Pipe Line Measurement by
host , not for the UFP internal CPL batch mode

4

6

automatic reset

75

B+RW

Modbus output for all totalisers and batch 1+2 values
on hold for 30 sec. (Internally all totalisers continue)

4

6

automatic reset

76

B+RW

During batch.

Guard Digital contact,

CLNT0300.DAT item 20.04 and 20.05,see also

Operating manual 10.4.3

4

6

automatic reset

77..200

Reserved

201

B+RW

API enable writing data

2

6

reset after 30 sec

202

B+RW

API change in: correction type

2

6

manual reset

203

B+RW

API change in: density standard type

2

6

manual reset

204

B+RW

API change in: fluid type

2

6

manual reset

205

B+RW

API change in: stand. density crude (fluid type 0)

2

6

manual reset

206

B+RW

API change in: stand. density gasoline (fluid type 1)

2

6

manual reset

207

B+RW

API change in: stand. density trans.area (fluid type 2)

2

6

manual reset

208

B+RW

API change in: stand. density jet group (fluid type 3)

2

6

manual reset

209

B+RW

API change in: stand. density fuel oil (fluid type 4)

2

6

manual reset

210

B+RW

API change in: stand. density free fill (fluid type 5)

2

6

manual reset

211

B+RW

API change in: free Fill K0

2

6

manual reset

212

B+RW

API change in: free Fill K1

2

6

manual reset

213

B+RW

API change in: free Fill K2

2

6

manual reset

214

B+RW

API change in: temperature standard

2

6

manual reset

215

B+RW

Change in: correction standard

2

6

manual reset

216

B+RW

Change in: ASTM-IP stand. density

2

6

manual reset

217

B+RW

Change in: LPG stand. density

2

6

manual reset

218

B+RW

Change in: LPG equilibrium pressure

2

6

manual reset

219..220

Reserved

221

B+RW

EXT enable writing data

8

6

automatic reset

222

B+RW

EXT change in: K-factor external flowmeter

8

6

manual reset

223

B+RW

EXT change in: parameters changeable under flowing
conditions or under low flow cuttoff

8

6

manual reset

224

B+RW

Change in: MeterFactor (Fwd)

1

6

if enabled in set-
up

225

B+RW

Change in: MeterFactor (Rev)

1

6

if enabled in set-
up

226..229

Reserved

230

B+RW

SYSTEM TIME deviation enable writing (see float 7577)

4

6

if enabled in set-
up

231

B+RW

SOLARTRON1 enable writing data

2

6

automatic reset

232

B+RW

SOLARTRON1 change in: calibration data

2

6

automatic reset

233

B+RW

SOLARTRON1 save and enable written data

2

6

automatic reset

234

B+RW

SOLARTRON2 enable writing data

2

6

automatic reset

235

B+RW

SOLARTRON2 change in: calibration data

2

6

automatic reset

236

B+RW

SOLARTRON2 save and enable written data

2

6

automatic reset

237

B+RW

SARASOTA1 enable writing data

2

6

automatic reset

238

B+RW

SARASOTA1 change in: calibration data

2

6

automatic reset

239

B+RW

SARASOTA1 save and enable written data

2

6

automatic reset

240

B+RW

SARASOTA2 enable writing data

2

6

automatic reset

241

B+RW

SARASOTA2 change in: calibration data

2

6

automatic reset

242

B+RW

SARASOTA2 save and enable written data

2

6

automatic reset

243

B+RW

OVERRIDE: enable writing data

1

2

6

automatic reset
30s

244

B+RW

OVERRIDE: change in: OVERRIDE data

1

2

6

automatic reset

Advertising