Dwyer GFT2 User Manual

Page 19

Advertising
background image

Index

81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163

Name

Total2_ReloadVolStop
Total2_ReloadDelay
Total2_10SecBackUp
Total2_Reserved
Flow_Pulse_Mode
PulseFlowStart
Units_Per_Pulse
Active_Low_Time
Flow_Pulse_Reserved
FlowCondMode
Flow_NRF_NSample
Flow_NRF_ErrLimit
Flow_NRF_TimeLimit
Flow_Damping
Flow_Window
FlowLinearizer
Flow_SC_Reserved
FlowTbl[0]. FlowPFSIn
FlowTbl[0]. FlowPFSOut
FlowTbl[1]. FlowPFSIn
FlowTbl[1]. FlowPFSOut
FlowTbl[2]. Flow PFSIn
FlowTbl[2]. Flow PFSOut
FlowTbl[3]. Flow PFSIn
FlowTbl[3]. Flow PFSOut
FlowTbl[4]. FlowPFSIn
FlowTbl[4]. FlowPFSOut
FlowTbl[5]. FlowPFSIn
FlowTbl[5]. FlowPFSOut
FlowTbl[6]. FlowPFSIn
FlowTbl[6]. FlowPFSOut
FlowTbl[7]. FlowPFSIn
FlowTbl[7]. FlowPFSOut
FlowTbl[8]. FlowPFSIn
FlowTbl[8]. FlowPFSOut
FlowTbl[9]. FlowPFSIn
FlowTbl[9]. FlowPFSOut
FlowTbl[10]. FlowPFSIn
FlowTbl[10]. FlowPFSOut
MDSerialNumber
MeterFSRange
LowFlowCutOff
FlowPowerUpDelay
Density
FluidName[20]
CalibratedBy[20]
CalibratedAt[20]
DateCalibrated[12]
DateCalibratedDue[12]
UserTagName
PSPTbl[0].PFS
PSPTbl[0].Time
PSPTbl[1].PFS
PSPTbl[1].Time
PSPTbl[2].PFS
PSPTbl[2].Time
PSPTbl[3].PFS
PSPTbl[3].Time
PSPTbl[4].PFS
PSPTbl[4].Time
PSPTbl[5].PFS
PSPTbl[5].Time
PSPTbl[6].PFS
PSPTbl[0].Time
PSPTbl[7].PFS
PSPTbl[7].Time
PSPTbl[8].PFS
PSPTbl[8].Time
PSPTbl[9].PFS
PSPTbl[9].Time
PSPTbl[10].PFS
PSPTbl[10].Time
PSPTbl[11].PFS
PSPTbl[11].Time
PSPTbl[12].PFS
PSPTbl[12].Time
PSPTbl[13].PFS
PSPTbl[13].Time
PSPTbl[14].PFS
PSPTbl[14].Time
PSPTbl[15].PFS
PSPTbl[15].Time
EEMagicNumber

Data Type

uint
uint
uint
uint
uint
float
float
uint
uint
uint
uint
float
uint
uint
uint
uint
uin
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
float
uint

Notes

Reload VolStop value when Totalizer reading counts down to zero 0 - No, 1 - Yes
Delay in seconds before Reload VolStop value when Totalizer reading counts down to zero [0-3600]
Enable or Disable every 10 seconds EEPROM backup (reserved for future version release)
Totalizer #2 reserved
Flow Pulse Output Mode (0=Disabled, 1=Enabled)
Start pulse output at flow [0-1.0 fraction notation %F.S.]
Units per pulse scaling
Number of ms output will be activated when pulse is developed
Pulse Output Reserved
0 - No conditioning, 1 - NRF, 2 - Running Average
Flow NRF Number of Samples [1 - 32]
Flow NRF Error Value [0.05 10.0] %F.S. (FN)
Flow NRF Time Interval [0-199], 0-disabled
Reading Damping 0-500 ms
Flow running average window [0-32] 0 - disable
Flow Linearizer: On (1), off (0)
Flow Signal Conditioner reserved
Flow Linearizer Index 0 PFS In (must be 0.0)
Flow Linearizer Index 0 PFS Out (must be 0.0)
Flow Linearizer Index 1 PFS In [0.0 - 1.0]
Flow Linearizer Index 1 PFS Out [0.0 - 1.0]
Flow Linearizer Index 2 PFS In [0.0 - 1.0]
Flow Linearizer Index 2 PFS Out [0.0 - 1.0]
Flow Linearizer Index 3 PFS In [0.0 - 1.0]
Flow Linearizer Index 3 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 4 PFS In [0.0 - 1.0]
Flow Linearizer Indes 4 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 5 PFS In [0.0 - 1.0]
Flow Linearizer Indes 5 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 6 PFS In [0.0 - 1.0]
Flow Linearizer Indes 6 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 7 PFS In [0.0 - 1.0]
Flow Linearizer Indes 7 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 8 PFS In [0.0 - 1.0]
Flow Linearizer Indes 8 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 9 PFS In [0.0 - 1.0]
Flow Linearizer Indes 9 PFS Out [0.0 - 1.0]
Flow Linearizer Indes 10 PFS In [0.0 - 1.0]
Flow Linearizer Indes 10 PFS Out [0.0 - 1.0]
Serial Number for Mated Device
Device FS range in Std. L/min
Must be between [0 and 0.1] fraction %F.S. notation [0-1.0]
Flow Power Up delay [0-1200] sec.
Fluid Density g/L
Name of the Fluid used for Calibration
Name of person meter was calibrated by
Name of the Calibration Lab
Calibration date
Date Calibration due
User Defined Device Tag Name or Number
PSP Table Index 0 Set Point PFS (0.0-1.0)
PSP Table Index 0 Time (sec)
PSP Table Index 1 Set Point PFS (0.0-1.0)
PSP Table Index 1 Time (sec)
PSP Table Index 2 Set Point PFS (0.0-1.0)
PSP Table Index 2 Time (sec)
PSP Table Index 3 Set Point PFS (0.0-1.0)
PSP Table Index 3 Time (sec)
PSP Table Index 4 Set Point PFS (0.0-1.0)
PSP Table Index 4 Time (sec)
PSP Table Index 5 Set Point PFS (0.0-1.0)
PSP Table Index 5 Time (sec)
PSP Table Index 6 Set Point PFS (0.0-1.0)
PSP Table Index 6 Time (sec)
PSP Table Index 7 Set Point PFS (0.0-1.0)
PSP Table Index 7 Time (sec)
PSP Table Index 8 Set Point PFS (0.0-1.0)
PSP Table Index 8 Time (sec)
PSP Table Index 9 Set Point PFS (0.0-1.0)
PSP Table Index 9 Time (sec)
PSP Table Index 10 Set Point PFS (0.0-1.0)
PSP Table Index 10 Time (sec)
PSP Table Index 11 Set Point PFS (0.0-1.0)
PSP Table Index 11 Time (sec)
PSP Table Index 12 Set Point PFS (0.0-1.0)
PSP Table Index 12 Time (sec)
PSP Table Index 13 Set Point PFS (0.0-1.0)
PSP Table Index 13 Time (sec)
PSP Table Index 14 Set Point PFS (0.0-1.0)
PSP Table Index 14 Time (sec)
PSP Table Index 15 Set Point PFS (0.0-1.0)
PSP Table Index 15 Time (sec)
Number used to verify EEPROM integrity

Advertising