Setting accuracy: The same as indicating accuracy
Action:

ON/OFF action

Hysteresis:

T/C and RTD input: 0.1 to 100.0°C (°F) [Factory adjusted as 1.0°C]

DC voltage and current input: 1 to 1000 [Factory adjusted as 10]
(Decimal point place follows the selection.)

Output:

Open collector, 24Vdc @ 0.100A maximum.

Alarm (EVT) output action: Alarm action is selectable from below by front key operation.

One alarm is selectable from High limit, Low limit,
High/Low limits, High/Low limit range, Process high,

Process low, High limit w/standby, Low limit w/standby,
High/Low limits w/standby and No alarm action
[Factory adjusted as No alarm action]

Energized/Deenergized: Alarm (EVT) output Energized/Deenergized can be selected.

[Factory adjusted as Energized]

Energized

Deenergized

Red (EVT) LED

Lights

Lights

Alarm output

ON

OFF

Alarm HOLD function selection: Once the alarm is activated, alarm output is remains

constant until power is turned off.

[Factory adjusted as: Alarm holding function Not used]

Loop break alarm (EVT) output is common with Alarm and optional Heater Burnout Alarm.

Detects heater burnout, sensor burnout, and abnormality at operation end.

Setting range:

Loop break alarm time setting: 0 to 200 minutes

[Factory adjusted as 0 minutes]

Loop break alarm action span setting

Thermocouple and RTD input: 0 to 150°C (°F) or 0.0 to 150.0 °C (°F)

[Factory adjusted as 0°C

DC voltage and current input: 0 to 1500

(Decimal point place follows the selection.)

Output:

Open Collector, 24Vdc @ 0.100A maxilmum.

Converter function: See Section 1, "Converter Function."
Insulation

• Dielectric strength

Circuit insulation structure

* When controls output is non-
contact voltage of DC Current,
there is no isolation between
the control output and the
communications option.

Insulated resistance: 10M

Ω or greater @ 500 Vdc except as noted above.

Dielectric strength: 1.5kVac for 1 minute between input terminal and power

terminal.

Power consumption Approx. 6VA
Ambient temperature 0 to 50°C (32 to 122°F)
Ambient humidity

35 to 85%RH (Non condensing)

Weight

Approx.150g (5.3 oz.)

Event output

CT input

Input

(5) (6) (7)

CPU

Insulation

Control output

Power supply

(8)

(9)

(1)

(2)

(3)

(4)

Communication

[Factory adjusted as 0]