3installation, 1 work rules, 2 installation requirements – Sterlco 2016C (Former Compact Series) User Manual
Page 17
COT-C Series Hot Oil Portable Temperature Control Units
Page 17
3
Installation
3-1 Work Rules
The installation, operation and maintenance of this equipment must
be conducted in accordance with all applicable work and safety
codes for the installation location. This may include, but is not
limited to OSHA, NEC, CSA, and any other local, national and
international regulations.
Read and follow these instructions when installing, operating
and maintaining this equipment. If the instructions become
damaged or unreadable, obtain additional copies from
STERLING.
Only qualified personnel familiar with this equipment should
work on or with this hot oil temperature control unit.
Work with approved tools and devices.
Disconnect the electricity before maintenance or service.
If the unit is installed with a power cord that can be un-
plugged, unplug it. If the unit is permanently wired to a
power main, make sure that a fused power disconnect is
installed to allow the disconnect to be locked in the
OFF
position. Open and lock out the disconnect installed in the
control enclosure.
3-2 Installation Requirements
Make sure that you meet the following requirements when
installing and operating your 2016-C hot oil temperature control
unit.
Installation Location Considerations
Locate the 2016-C unit as close as possible to the process for
proper circulation and temperature control. Take care when
selecting a location. The area surrounding the unit must be free of
obstructions to ensure proper ventilation of internal components.
Allow a minimum clearance of at least 30 inches (76 cm).