COT-C Series Hot Oil Portable Temperature Control Units

Page 21

!

CAUTION

The reservoir tank must be vented to prevent pressurization.

A pressurized reservoir could rupture, allowing hot fluid

to escape and become a potential fire and slip hazard.

Note: Heat transfer fluids expand when heated. Expansion rates

vary, depending on fluid types and temperatures. For more
information on expansion rates, refer to specification
information for the heat transfer fluid you select.


Generally, most heat transfer fluids expand at the rate of
2.5% for every increase of 50°F/°C from temperatures
above 60°F (16°C).


Figure 2

2016-C Unit Piping Setup

Connect the

TO PROCESS

hookup to the

entrance of the process and the

FROM

PROCESS

hookup to the exit of the process.

Connect the

COOLING WATER SUPPLY

to

your plant water supply. Connect the

COOLING WATER DRAIN

line to an open

drain, or to the return line of your central
water system. If returning to a central water
system, use a condensate/return tank to
avoid a standing water column on the heat
exchanger drain line.