Settings and adjustments – Sterlco ST500 Series Central Granulator User Manual

Page 48

Advertising
background image

48

SETTINGS AND ADJUSTMENTS

SECTION 4-14

Adjusting or Replacing Rotor Knives

TIGHTEN THE ROTOR KNIVES TO FINAL TORQUE

Use a 30 mm socket wrench to tighten the mounting screws on each knife in small

steps keeping them about even as you increase the torque on them.

Use a torque wrench to apply the final torque of 472 ft lbs (640 Nm) to the

mounting screws. Make sure your footing is secure before you apply the final

torque.

Check with a 0.0015" (0.04 mm) feeler gage to ensure that each knife is snug

against the knife seat.

CHECK THE BED KNIVES

If the bed knives have been removed, check them as follows:

Check both halves of the upstroke knife (the bed knife on the far side of the rotor) to be sure

that the cutting edges face down.

Check both halves of the down-stroke knife (the bed knife on the near side of the rotor) to

be sure that the cutting edges face up.

GAP ADJUSTMENT TIPS

It is best to keep the adjustments on the captive screws moving in the same direction. This

eliminates the effect of backlash in the adjusting screw.

Make the screw adjustments in small steps to keep the bed knife adjustment even over the

width of the machine.

To avoid cutting the shim stock, turn the rotor backward during the adjustment procedure.
Use the rotor knife with the largest dimension from rotor centerline as the reference, i.e., the

highest knife.

MEASURE THE KNIFE GAP

Use brass shim stock to set the knife gap to the cutting

clearance of 0.006 in. to 0.008 in. (0.15 mm to 0.20 mm).

Remove the rotor-locating pin.

Rotate the rotor backward, by hand, and measure the gap

between it and the bed knife at the point of shear. You

can work on each half of the bed knife independent of the

other half but keep them in step with each other by

working from side-to-side.

Advertising