Settings and adjustments – Sterlco ST500 Series Central Granulator User Manual

Page 56

Advertising
background image

56

SETTINGS AND ADJUSTMENTS

SECTION 4-22

Setting and Adjusting the Rear Chamber Pneumatic Cylinder

OVERVIEW

Proper adjustment of pneumatic cylinder is important to performance and safety. Improper settings can

result in premature failure of the jackscrews.
To avoid severe damage to the cylinders, BE PREPARED TO SHUT THEM DOWN IMMEDIATELY

WHEN THE CHAMBER IS MOTIONLESS FOR ANY REASON WHILE THE MOTORS ARE

RUNNING. This condition can occur when the chamber jams on debris or when the chamber reaches

the end of its stroke, whether on the opened or closed end of the stroke (if the limit switches are not

properly adjusted).

TURN OFF AND LOCKOUT the power per OSHA 1910.147 OR ANSI Z244.1-1982 (Lockout/Tag-

out of Energy Sources).

If it is not possible to lock out the power, have an electrician remove the fuses.

Make sure the rotor has come to a complete stop.

The pneumatics, which open the rear of the machine, should not operate until the power is completely

off. If you discover that the pneumatics DO operate while the power is still on, immediately shut down

the machine and call for maintenance to adjust it.

Wear gloves to protect against injury from the rotor or bed knives.