Table 5 – HP XP Array Manager Software User Manual
Page 30
2.
See
, page 30 for a description of the error code.
For details about the error codes that are not described in
, page 30, contact your HP
Service Representative (see
).
Table 5 Error Codes and Error Contents When Using RAID Manager
Description
Error Code (SSB2)
Error Code (SSB1)
The setting failed because the specified volume does not
exist.
B9BD
B9BF/B9BD
The specified volume is a command device.
B9C2
The command was rejected due to one of the following
reasons:
B9C4
•
The specified volume is a P-VOL or S-VOL of XP Snap-
shot
•
The specified volume is a virtual volume.
•
The specified volume is a pool volume.
•
The specified volume is an S-VOL of XP XP Continuous
Access Journal.
•
The specified volume is a journal volume.
•
The specified volume is reserved for the XP Auto LUN
function.
•
The specified volume is a P-VOL or S-VOL of XP XP
Business Copy.
•
The consumed capacity exceeded the licensed capacity.
•
The access attribute cannot be changed because the
data retention term is set.
•
The specified volume is a command device.
•
The specified volume is in the PAIR or COPY status.
•
The specified volume does not exist.
•
The S-VOL Disable attribute is set to the specified
volume.
•
The reserve function cannot be canceled by RAID
Manager.
The Data Retention Utility is not installed.
B9C7
The consumed capacity exceeded the licensed capacity.
B9C9
Either:
B9CA
•
More than 60 years are set as the data retention days,
or
•
The other interface updated the settings while the Data
Retention Utility was changing the settings (Java conflic-
ted with the other interface).
The data retention term cannot be set because the access
attribute is set to Read/Write.
B9CB
Troubleshooting
30