HP 3PAR Operating System Software User Manual

Page 277

Advertising
background image

0:0:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

0:2:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

0:2:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

0:3:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

0:3:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

1:0:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

1:0:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

1:3:1 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

1:3:2 Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

------------------------------------------------------------------------

total Data t 0 0 0 0 0 0 0.0 0.0 0.0 0.0 0

The columns in the example above are identified as follows:

Port.

The port ID.

D/C.

The Data or Control transfers.

r/w.

The I/O type. Values can be read (r), write (w), or read and write (t).

I/O per second Cur.

The current number of I/O per second.

I/O per second Avg.

The average number of I/O per second.

KBytes per Max.

The maximum number of KB per second.

KBytes per Cur.

The current number of KB per second.

KBytes per Avg.

The average number of KB per second.

Svt ms Max.

The maximum service time in milliseconds.

Svt ms Cur.

The current service time in milliseconds.

Svt ms Avg.

The average service time in milliseconds.

IOSz KB Cur.

The current I/O size in KB.

IOSz KB Avg.

The average I/O size in KB.

Qlen.

The queue length.

Util % Cur.

The percentage of current use.

Util % Avg.

The percentage of average use.

NOTES

See the HP 3PAR InForm OS CLI Reference for additional information for this command, including
additional options, restrictions, and examples.

277