NOTE:

The minimum number of network connections is two. You cannot remove these two

default connections. You cannot add more than the maximum allowed network connections.
The maximum allowed network connections is based on the VC firmware mode. For more
information see the HP Virtual Connect Enterprise Manager User Guide available at:

http://

www.hp.com/go/vcem/

.

Select from the following Flex-10 iSCSI network connection options:

Add Flex-10 iSCSI network connections by using the -add iscsi-connection
command.

Modify Flex-10 iSCSI network connections by using the -set iscsi-connection
command.

Remove Flex-10 iSCSI network connections by using the -remove iscsi-connection
command.

NOTE:

You can remove all of the iSCSI connections. You cannot add more connections than

the maximum allowed. The maximum connections allowed is based on the VC firmware mode.
For more information, see the HP Virtual Connect Enterprise Manager User Guide available
at:

http://www.hp.com/go/vcem/

.

Select from the following FC connection options:

Add FC SAN connections by using the -add fc-connection command.

Modify FC SAN connections by using the -set fc-connection command.

Remove FC SAN connections by using the -remove fc-connection command.

NOTE:

You can remove all of the FC connections. You cannot add more connections than

the maximum allowed.

Edit the FC boot parameters by using the -set fc-connection command.

Select from the following FCoE connection options:

Add FCoE connections by using the -add FCoE-connection command.

Modify FCoE connections by using the -set FCoE-connection command.

Remove FCoE connections by using the -remove FCoE-connection command.

Edit the FCoE boot parameters by using the -set FCoE-connection command.

Select from the following iSCSI boot-parameter options:

Add iSCSI boot parameters by using the –set iscsi-boot-param command.

Modify iSCSI boot parameters by using the –set iscsi-boot-param command.

Remove iSCSI boot parameters by using the -remove iscsi-boot-param command.
You can’t add more than two boot parameters on the iSCSI connection.

NOTE:

You cannot add more than two boot parameters on the iSCSI connection.

Change the server profile’s bay assignment by using the –unassign profile command,
the –assign profile command, or the -move profile command.

Server profiles can be moved within as well as between VC domain groups. The assign and
unassign commands work within a domain group. The move command can work within as