Poweron devicebay, Syntax, Parameters – HP Insight Management-Software User Manual

Page 72: Output, Examples, Minimum required role-based security, Remarks, Prerequisites

Advertising
background image

poweron devicebay

The -poweron devicebay command sends a power-on request to Virtual Connect Manager for
a given bay.

Syntax

-poweron devicebay -enclosurename <enclosurename> -bayname <bayname>

Parameters

Table 30 Parameter descriptions for -poweron devicebay

Optional

Required

Description

Parameter

x

Specifies the name of the
enclosure that contains the
bay to be powered on.

-enclosurename

x

Specifies the name of the
bay to be powered on.

NOTE:

For a multiblade

server, the bay name must
be the name of the primary
bay.

-bayname

Output

The result of the power-on operation. If –nb is in effect for the command, nothing is returned, and
you can verify the results of the command by polling -show power-status for the enclosure
bay.

Examples

Power on a specific server in bay 2 of the enclosure enc0:

vcemcli -poweron devicebay –enclosurename enc0 –bayname 2

Power on a specific multi-blade server that occupies bays 1 to 4 of the enclosure enc0:

vcemcli -poweron devicebay –enclosurename enc0 –bayname 1

Minimum required role-based security

VCEM Group Limited Operator

Remarks

When –nb is specified, this command does not indicate that the power has actually been turned
on. It is only an indication that the request has been successfully passed to Virtual Connect Manager.
The –show power-status command must be polled to determine whether the bay has been
successfully powered on. An error is reported if the bay or enclosure name is invalid.

NOTE:

When a timeout is specified, this command will block and poll the power status on an

interval defined by pollinginterval until the timeout is reached. A return of success means
the power is successfully turned on. The VCEMCLI will wait for a maximum of 3600 seconds (1
hour) by default when no timeout has been specified for the command.

Prerequisites

The bay must contain a server.

72

Using VCEM commands

Advertising
This manual is related to the following products: