Table 20 TSO Command Parameters
Command
Parameter
Value
Description
DEVN
Device number
PRIM
Primary volume
(S-VOL): SSID, serial
number, channel
connection address,
CU number. You can set
an additional parameter
for each request instead
of a serial number.
1. For an Add and
Split request (see section
” on page 82), the
parameter is MSF00.
This parameter is valid
for MODE(COPY) only.
2. For a Quick Resync
request, the parameter
is MRF00. This
parameter is valid for
MODE(RESYNC) only.
3. For a Quick Restore
request, the parameter
is MRQ00. This
parameter is valid for
MODE(RESYNC) only.
4. For a Reverse
Copy request, the
parameter is MRR00.
This parameter is valid
for MODE(RESYNC) only.
If you set a parameter
other than the parameters
listed at the left, the
command is rejected. CU
number or parameter is
valid only for the disk
controller emulation type
2105 or 2107
SEC
Secondary volume
(T-VOL): SSID, serial
number, channel
connection address,
CU number
COPY
NOCOPY
Whether you specify
COPY or NOCOPY for
the MODE parameter,
the storage system
recognizes it as COPY
mode. Therefore, initial
full-volume copy is
performed.
MODE
RESYNC
Re-establish a split or
suspended volume pair.
1
Copy speed is slow,
except when the disk
controller emulation
type is 2105 or 2107.
When the disk controller
emulation type is 2105 or
2107, the copy speed
is always medium
regardless what you
specify for the PACE
parameter.
PACE
Other than 1
Copy speed is medium.
CRIT
Not applicable.
Siz does not use this
parameter. Siz ignores it.
YES
MSGREQ function is
applicable.
MSGREQ
NO
MSGREQ function is not
applicable.
CESTPAIR
Hitachi ShadowImage for z/OS user guide
101