Hp bladetype-4 network mibs (gbe2c-l2l3.mib) – HP Insight Management for Tivoli User Manual
Page 165
Appendix B: HP SNMP events 165
Trap types
Rules file
Description
Netcool
severity
alarmWaterCoolUnit (6)
—
This event occurs when status of
Water Cool Unit sensor unit changes.
—
CpqWcrmWaterCoolUnitStatus
:ok
CpqWcrmWaterCo
olUnitStatus.1
—
Clear (0)
CpqWcrmWaterCoolUnitStatus
:error
CpqWcrmWaterCo
olUnitStatus.2
—
Major (4)
CpqWcrmWaterCoolUnitStatus
:changed
CpqWcrmWaterCo
olUnitStatus.3
—
Minor (3)
CpqWcrmWaterCoolUnitStatus
:reset
CpqWcrmWaterCo
olUnitStatus.4
—
Minor (3)
CpqWcrmWaterCoolUnitStatus
:timeout
CpqWcrmWaterCo
olUnitStatus.5
—
Minor (3)
CpqWcrmWaterCoolUnitStatus
:detected
CpqWcrmWaterCo
olUnitStatus.6
—
Minor (3)
CpqWcrmWaterCoolUnitStatus
:notAvail
CpqWcrmWaterCo
olUnitStatus.7
—
Major (4)
CpqWcrmWaterCoolUnitStatus
:lowPower
CpqWcrmWaterCo
olUnitStatus.8
—
Major (4)
testTrap (10)
10
This is a test trap to check proper
reception on traps.
Clear (0)
HP Bladetype-4 Network MIBs (GbE2c-L2L3.MIB)
Trap types
Rules file
Description
Netcool
severity
bntSwDefGwUp (2)
2
This event occurs when the default
gateway is up.
Clear (0)
bntSwDefGwDown (3)
3
This event occurs when the default
gateway is down.
Clear (0)
bntSwDefGwInService (4)
4
This event occurs when the default
gateway is up and in service.
Clear (0)
bntSwDefGwNotInService (5)
5
This event occurs when the default
gateway is up but not in service.
Clear (0)
bntSwLoginFailure (19)
19
This event occurs when a valid
username/password combination is
not entered.
Major (4)
bntSwTempExceedThreshold (22) 22
This event occurs when the switch
temperature exceeds maximum safety
limits.
Critical (5)
bntSwApplyComplete (27)
27
This event occurs when a new
configuration is applied.
Clear (0)
bntSwSaveComplete (28)
28
This event occurs when a new
configuration is saved.
Clear (0)
bntSwFwDownloadSucess (29)
29
This event occurs when the firmware
is downloaded.
Clear (0)