Systems information (cpqsinfo.mib) – HP Insight Management for Tivoli User Manual
Page 23
Appendix B: HP SNMP events 23
Trap types
Rules file
Description
Netcool
severity
cpqSePCCardThermalDegr
aded (1002)
1002
This event occurs when the PC Card
Slot Thermal Sensor threshold has
been exceeded for safe operations
thereby causing degraded
operations.
Major (4)
cpqSePCCardThermalFailur
e (1003)
1003
This event occurs when the PC Card
Slot Thermal Sensor threshold has
been exceeded for degraded
operations, thereby causing failed
operations.
Critical (5)
cpqSePCCardThermalSafe
(1004)
1004
This event occurs when the PC Card
Slot Thermal Sensor threshold has
been crossed, which restored the
thermal status to normal operations.
Clear (0)
cpqSe2CpuThresholdPasse
d (1005)
1005
This event occurs when an internal
CPU error threshold has been
passed on a particular CPU causing
it to go degraded.
Minor (3)
CpqSeCpuStatusChange
(1006)
—
This event occurs when the CPU
status changes.
—
cpqSeCpuStatus:ok
cpqSeCpuStatus.2
—
Clear (0)
cpqSeCpuStatus:degraded cpqSeCpuStatus.3
—
Major (4)
cpqSeCpuStatus:failed
cpqSeCpuStatus.4
—
Critical (5)
cpqSeCpuStatus:disabled
cpqSeCpuStatus.5
—
Minor (3)
CpqSeCpuPowerPodstatusC
hange (1007)
—
This event occurs when the CPU
Power Pod status changes.
—
cpqSeCpuPowerpodStatus:
NotFailed
cpqSeCpuPowerpodSta
tus.1
—
Clear (0)
cpqSeCpuPowerpodStatus:
Failed
cpqSeCpuPowerpodSta
tus.2
—
Critical (5)
cpqSeUSBStorageDeviceAtt
ached
1008
This event occurs when a USB
device is inserted.
Clear (0)
cpqSeUSBStorageDeviceRe
moved
1009
This event occurs when a USB
device is removed.
Clear (0)
Systems information (CPQSINFO.MIB)
Trap types
Rules file
Description
Netcool
severity
cpqSiHoodRemoved (2001) 2001
This event occurs when hood status
has been set to removed.
Major (4)
cpqSiMonitorConditionOK
(2002)
2002
This event occurs when the Fault
reporting features have returned to
within their normal operating range
for the monitor.
Clear (0)