12 enabling the wiper, 1 enable from the remote button, 2 enable from the keyboard – Videotec MAXIMUS MHXT User Manual

Page 31: 13 enable the washing system from the keyboard

Advertising
background image

Instruc

tions manual - English - EN

31

7.3.12 Enabling the wiper

7.3.12.1 Enable from the remote button

The wiper can be operated remotely using an NO

(normally open) clean contact. The command has

a range of about 200m (656ft) and can be achieved

with an unshielded cable with a 0.25mm² minimum

section (AWG 24).

WIPER_CMD

clean contact

Fig. 37

Pass the cables through the entry device.
Pull out the J6 removable connector (WIPER_CMD)

from the CPU board and connect the cables.
Then insert the wired connector into the connector

and connect the cables with a cable tie.

All signal cables must be grouped together

by means of a strap.

J3

J8

J6

Fig. 38

Before closing the housing, connect the

wiper wiring to the J3 and J8 connectors.

7.3.12.2 Enable from the keyboard

If the serial communication line is being used, the

wiper can be enabled from the keyboard.

7.3.13 Enable the washing system from

the keyboard

If the serial communication line is being used, the

washer can be enabled from the keyboard. The

washer is activated via the closure of the clean

contact of a relay. Due to the absence of polarity both

terminals of the same relay can be used alternately

with voltages of alternating or direct current.
Pass the relays cables through the entry device.
Pull out the J11 removable connector (OUT_Washer)

from the CPU board and connect the relay cables
Then insert the wired connector into the connector

and connect the cables with a cable tie.

Fig. 39

Advertising
This manual is related to the following products: