7.3.14 Enable an external illuminator

from the day/night camera output

The camera could be equipped with a day/night

clean contact output that can be used to enable an

external illuminator.
Connect the camera's day/night output to the CPU

board's J4 input.

Fig. 40

The illuminator is activated via the closure of the

clean contact of a relay.
Relays do not have polarity and therefore both

terminals of the same relay can be swapped for

alternating or continuous current voltages.
Pass the relays cables through the entry device.

Remove the removable J5 (OUT_Day/Night) from the

CPU board and connect the relay cables.
Re-insert the wired connector into the board and

connect the cables with a cable tie.

Fig. 41

Relays can be used for low working

voltages only (up to 30Vac or 60Vdc) and

with a maximum current of 1A. Use cables

with a section suitable for the load to be

controlled and use cables with a minimum

section of 0.25mm² (AWG 30) and maximum

section of 1.5mm² (AWG 16).