Power hook-up, Air spinmaster – Hawk Industries Spinner Manual 550 HYDRAULIC Serial Numbers 1 to 205 User Manual
Page 11
![background image](/manuals/460492/11/background.png)
11
Installation
Power Hook-Up
Hydraulic Spinmaster
HIS
HOS
1. The hydraulic Spinmaster
requires a minimum hydraulic
pressure of 2000psi and a maxi-
mum pressure of 2500psi.
2. The hydraulic Spinmaster re-
quires a minimum hydraulic
volume of 20 GPM and a maxi-
mum of volume of 30GPM.
3. Connect (at least) a 3/4" hy-
draulic pressure hose (3000psi
working) to the hydraulic inlet
side ( HIS ) of the Spinmaster
valve as shown.
4. Connect (at least) a 1" hydrau-
lic return hose (250psi working)
to the hydraulic outlet side(HOS)
of the Spinmaster valve as
shown.
ASL
HRL
HPL
HRL
HPL
1. Connect the three supply hoses
(supplied with the Spinmaster):
the Hydraulic Return Line
(HRL), the Hydraulic Pressure
Line (HPL), and the Air Supply
Line (ASL) to the Spinmaster
and the Air Power Pack (APP)
as shown.
Continued on Next Page
APP
Note
Hydraulic filtration (at least 25
micron) is highly recommended
for Spinmaster for performance
and reliablity.
Air Spinmaster
ASL