Meteor DMX Relay User Manual

Page 2

Advertising
background image

Page 2 of 3

MLSC Inc (Meteor Light and Sound Co.)

Mailing address: P.O. BOX 578; Shipping: 8000 Madison Pike, Madison, AL 35758
Phone: (256) 461-8000 Sales: (256) 772-9626 Fax: (256) 461-7708
[email protected] www.meteor-usa.com www.meteor-global.com

Switching Line Voltage Loads:

The Universal DMX Relay's input line voltage is switched to a standard NEMA type 5-15R receptacle. Up
to a 15A inductive or non-inductive load is permitted. The relay will close energizing the load whenever
the DMX level being decoded rises above 127. The relay will open de-energizing the load whenever the
level falls below 128.

Switching Low Voltage Loads:

Low voltage loads are easily switched utilizing the secondary switch closures labeled 'relay 1a' and 'relay
1b' found on the 6 position terminal strip. Limit low voltage loads to a maximum of +-48V and 3 amps.


+-5V / 10V Logic Level Switching:


The 6 position terminal strip allows for a variety of switching configurations. The following diagrams
demonstrate possible solutions to common switching task:


































relay 1a

relay 1b

+10vdc

+5vdc

ground

pull



Active Low

GND

Negative 10V Logic

relay 1a

relay 1b

+10vdc

+5vdc

ground

pull



Active High

GND

Positive 10V Logic

relay 1a

relay 1b

+10vdc

+5vdc

ground

pull



Active High

GND

Positive 5V Logic

relay 1a

relay 1b

+10vdc

+5vdc

ground

pull



Active Low

GND

Negative 5V Logic

Advertising