Meteor DMX Relay User Manual

Page 3

Advertising
background image

Page 3 of 3

MLSC Inc (Meteor Light and Sound Co.)

Mailing address: P.O. BOX 578; Shipping: 8000 Madison Pike, Madison, AL 35758
Phone: (256) 461-8000 Sales: (256) 772-9626 Fax: (256) 461-7708
[email protected] www.meteor-usa.com www.meteor-global.com

DMX Line Monitor:

The Universal DMX Relay is equipped with a comprehensive DMX line monitor designed to help isolate
common line problem.

ERROR CODES

DMX LED

RELAY LED

POSSIBLE FAULT

Full On

or Off

3 second flutter

followed by 2

seconds Off

Disconnected or cut data cable,

Control signal not present

Dim or Fluttering

3 second flutter

followed by 2

seconds Off

Reversed data lines

(pins 2 & 3 swapped),

Invalid DMX512 control signal



LED Indicators:

Power - The red power indicator will illuminate whenever line voltage is applied. If the indicator
fails to light you should check that the 15A fuse is not blown and that correct line voltage is being
applied.

DMX - The green dmx indicator will flutter or light dimly when a valid DMX512 signal is
present.

Relay - The yellow relay indicator will illuminate whenever the relay is active. Line voltage will
be present at the output connector and the low voltage relay contact will be closed. The indicator
will flutter for 3 seconds and turn Off for 2 seconds in the event of DMX line errors.


DMX Line Termination:

The Universal DMX Relay is equipped with a user selectable 120 ohm terminating resistor. To enable line
termination set dip switch number 10 to the ON position. Line termination should only be activated when
the Universal DMX Relay is the last unit in the chain of units.

Advertising