Maintenance
3. For the M and L group pumps, tighten the jacking screws (418) until the gap between the
clamp ring (141C) and the C-face motor support and bearing frame is 3.50 in. (8.89 cm).
4. For all pumps except the V group, grasp the suction flange of the casing and pull the
casing-liquid end free from the magnet assembly.
5. For all pumps except the SP group, remove the casing bolts (356A).
6. Wrap a piece of emery cloth around the containment shell (750) and secure it with a large
hose clamp.
Figure 20: V group
Figure 19: SP group
Figure 21: XS, X, S, M, and L groups
7. Disassemble the containment shell:
a) Screw the C-face motor support and bearing frame bolts (370B) into the tapped holes
of the clamp ring (141C) and tighten evenly in order to remove the containment shell.
b) Remove the O-ring (412M) from the containment shell (750) and discard it.
c) Remove the hose clamp and emery cloth.
3298 Family Installation, Operation, and Maintenance Manual
57