Disassemble the frame-mounted pump – Goulds Pumps 3298 - IOM User Manual
Page 61
Maintenance
11. Inspect and replace these parts as necessary:
Pump group
Step
M and L
Inspect the rear impeller wear ring (203) and remove it if replacement is
necessary.
L
Remove the retaining ring (361H). Then slide or press the magnet
assembly (740A) off the impeller assembly (101).
Figure 26: L group
S, M, and SP, and V
Remove the reverse thrust bearing (197C) from the containment shell
(750) if replacement is necessary.
12. When replacement of the close-coupled drive magnet assembly (740B) is required, remove
and discard the nylok setscrews (222L).
Use a puller and the 2 - 3/8-inch tapped holes provided in order to remove the magnet
assembly from the motor shaft.
Disassemble the frame-mounted pump
1. Place a shaft wrench on the drive shaft (122B) and remove the hex nut (355A).
Figure 27: S, L, M, and SP groups
2. Place three capscrews in the jacking screw holes in the magnet assembly (740B).
Group
Capscrew size
S and SP
5/16 in. by 2 in.
M and L
5/8 in. by 4 in.
3298 Family Installation, Operation, and Maintenance Manual
59