1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all

power cords from electrical outlets and disconnect all cables that are connected to the server.

2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 69.

3. Remove the server cover. See “Removing the server cover” on page 69.

4. Touch the static-protective package that contains the ThinkServer RAID Super Capacitor Module to

any unpainted surface on the outside of the server. Then, take the ThinkServer RAID Super Capacitor
Module out of the package.

5. Note the orientation of the ThinkServer RAID Super Capacitor Module. Then, gently press the tab

on the cooling shroud as shown and install the ThinkServer RAID Super Capacitor Module onto the
cooling shroud at the same time.

Figure 111. Installing the ThinkServer RAID Super Capacitor Module onto the cooling shroud

6. Connect the ThinkServer RAID Super Capacitor Module to a RAID card.

What to do next:

• To work with another piece of hardware, go to the appropriate section.

• To complete the installation, go to “Completing the parts replacement” on page 183.

Removing the ThinkServer RAID Super Capacitor Module

Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii
and “Guidelines” on page 67.

Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.

Note: Use any documentation that comes with the ThinkServer RAID Super Capacitor Module and follow
those instructions in addition to the instructions in this topic.

To remove the ThinkServer RAID Super Capacitor Module, do the following:

1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all

power cords from electrical outlets and disconnect all cables that are connected to the server.

2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 69.

3. Remove the server cover. See “Removing the server cover” on page 69.

4. Disconnect the cable of the ThinkServer RAID Super Capacitor Module from the RAID card.

Chapter 6

.