Whirlpool WFG540H0AS User Manual

Whirlpool Kitchen

Advertising
background image

30" (76.2 cm) Freestanding Gas Range

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

CABINET OPENING DIMENSIONS

WFG540H0A

WFG710H0A

WFG714HLA

WFG720H0A

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10553363A

7/9/13

A

B

C

D

E

F

A. 27

⁷⁄₈" (70.8 cm) max. depth with handle

B. 36" (91.4 cm) cooktop height (max.) with leveling legs

screwed all the way in*

C. 46

⁷⁄₈" (119.1 cm) overall height (max.) with leveling legs

screwed all the way in*

D. 29

⁷⁄₈" (75.9 cm) width

E. 25

⁷⁄₁₆" (64.6 cm) depth. Back of range to front of cooktop**

F. Model/serial rating plate (located on the oven frame behind

the top right side of the oven door)

IMPORTANT: Range must be level after installation. Follow the instructions in the
“Level Range” section. Using the cooktop as a reference for leveling the range is not
recommended.

*

* Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.

** Front of door and drawer may extend farther forward, depending on styling.

M

H

A

B

C

D

E

L

G

I

K

J

F

A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth

C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of cooktop, see NOTE*.

E. 30

¹⁄₈" (76.5 cm) min. opening width

F. The shaded areas are recommended for installation of rigid

gas pipe.

G. 11" (27.9 cm)

H. 17" (43.2 cm)

I. 2" (5.1 cm)

J. 4

¹⁄₂" (11.4 cm)

K. 3" (7.6 cm) min. clearance from both sides of range to side

wall or other combustible material.

L. Grounded outlet

M. Cabinet door or hinges should not extend into the cutout.
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered

by not less than

¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than

No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the
bottom of an uncovered wood or metal cabinet.

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth,
24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above
the range, follow the range hood or microwave hood combination installation
instructions for dimensional clearances above the cooktop surface.

Type of Gas
Natural Gas:

This range is design-certified by CSA International for use with Natural gas or, after proper

conversion, for use with LP gas.

This range is factory set for use with Natural gas. See “Gas Conversions” section. The
model/serial rating plate located on the oven frame behind the top right side of the oven door has
information on the types of gas that can be used. If the types of gas listed do not include the type
of gas available, check with the local gas supplier.

LP gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate
for use with a different gas without consulting the serving gas supplier. See “Gas Conversions” section.
Gas Supply Line

Provide a gas supply line of

³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer

runs may result in insufficient gas supply. With LP gas, piping or tubing size can be

¹⁄₂" (1.3 cm)

minimum. Usually, LP gas suppliers determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON

®†

tape.

Flexible metal appliance connector:

If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long,

¹⁄₂" (1.3 cm) or

³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may be used

for connecting range to the gas supply line.

A

¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the

female pipe threads of the inlet to the appliance pressure regulator.

Do not kink or damage the flexible metal tubing when moving the range.

Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to
the range. The rigid pipe must be level with the range connection. All
strains must be removed from the supply and fuel lines so range will be
level and in line.

Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should be located in the
same room but external to the range opening, such as an adjacent cabinet. It should be in a
location that allows ease of opening and closing. Do not block access to shutoff valve. The valve
is for turning on or shutting off gas to the range.

Electrical
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is recommended that a separate
circuit serving only this range be provided.

†®

TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

A. Gas supply line
B. Shutoff valve “open” position

C. To range

A

B

C

Advertising
This manual is related to the following products: