27" (68.6 cm) and 30" (76.2 CM) ELECTRIC BUILT-IN
MICROWAVE/OVEN COMBINATION

PRODUCT MODEL SERIES

PRODUCT DIMENSIONS

WOC54EC0A

WOC54EC7A

WOC95EC0A

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and the wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code,
ANSI/NFPA 70-latest edition or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest
edition, and all local codes and ordinances.
To properly install your oven, you must determine the type of
electrical connection you will be using and follow the
instructions provided for it here.

Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial number rating
plate. The model/serial number rating plate is located near
center vent of the lower oven. See the following illustration.

Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to
7.4 kW at 208 volts) require a separate 40-amp circuit. Models
rated at 4.8 kW and below at 240 volts (3.6 kW and below at
208 volts) require a separate 20-amp circuit.

A circuit breaker is recommended.

Connect directly to the fused disconnect (or circuit breaker
box) through flexible, armored or nonmetallic sheathed,
copper cable (with grounding wire). See “Make Electrical
Connection” section.

Flexible conduit from the oven should be connected directly to
the junction box.

Do not cut the conduit. The length of conduit provided is for
serviceability of the oven.

A UL listed or CSA approved conduit connector must be
provided.

If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of copper

wire using special connectors and/or tools designed and UL
listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
For power requirements for models WOC54EC7A, WOC54EC0A,
WOC95EC0A and MMW9730A, refer to the following table.
Voltage

Microwave Oven and

Microwave Oven and

Microwave Oven with

Microwave Oven with

Single Thermal Oven

Single Convection Oven

240 VAC

5490 W

5520 W

208 VAC

4590 W

4620 W

240 VAC

30.4 A

30.5 A

208 VAC

28.4 A

28.6 A

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10351241

6/26/12

B

A

C

D

E

F

E

A

D

G

B

C

Product Dimensions

Cabinet Dimensions

*NOTE: The cabinet height can be between 41" (104.1 cm) and

41½" (105.6 cm) for microwave/oven combination.

A.

30

" (76.2 cm) min. cabinet width

B. 1" (2.5 cm) top of cutout to bottom

C. 19

¹⁄₄

" (48.9 cm) bottom of cutout to

4"-19

¹⁄₄

" (10.2-48.9 cm) bottom of

D. 28

¹⁄₂

" (72.4 cm) cutout width

E. 1

¹⁄₂

" (3.8 cm) min. bottom of cutout

F. 41

⁵⁄₁₆

" (105 cm)* recommended cutout

G. 24" (60.7 cm) cutout depth

30" (76.2 cm) models

A.

42⁹⁄₁₆

" (108.0 cm) overall height

B. 28

¹⁄₂

" (72.3 cm) recessed width

C. 41" (104.1 cm) recessed height
D. 23

¹⁄₄

" (59.1 cm) max. recessed depth

E. 30" (76.2 cm) overall width

27" (68.6 cm) models

A.

42⁹⁄₁₆

" (108.0 cm) overall height

B. 25

⁷⁄₁₆

" (64.6 cm) recessed

width

C. 41" (104.1 cm) recessed height
D. 23

¹⁄₄

" (59.1 cm) max. recessed

depth

E. 27" (68.6 cm) overall width

27" (68.6 cm) models

A. 27" (68.6 cm) min. cabinet

width

B. 1" (2.5 cm) top of cutout to

bottom of upper cabinet door

C. 19

¹⁄₄

" (48.9 cm) bottom of

cutout to floor is
recommended.
4"-19

¹⁄₄

" (10.2-48.9 cm) bottom

of cutout to floor is acceptable.

D. 25

¹⁄₂

" (64.8 cm) cutout width

E. 1

¹⁄₂

" (3.8 cm) min. bottom of

cutout to top of cabinet door

F. 41

⁵⁄₁₆

" (105 cm)* recommended

cutout height

G. 24" (60.7 cm) cutout depth

30" (76.2 cm) models

of upper cabinet door

floor is recommended.

cutout to floor is acceptable.

to top of cabinet door

height

A. Model/serial number plate