Hale HP Series User Manual

Page 35

Advertising
background image

USER OPERATION AND MAINTENANCE

HP SERIES

PORTABLE PUMPS

35

13. Check area around pump for oil

leaks.

14. Return pump to storage area.

DUAL ELEMENT AIR CLEANER

The air cleaner consists of a foam

pre-cleaner and a paper cartridge. The

foam pre-cleaner should be serviced

after every 25 hours of pump operation

or weekly. The paper cartridge should

be serviced after every 100 hours of

pump operation or yearly.

WARNING: TO PREVENT
ACCIDENTAL STARTING
when
servicing the engine or pump
always disconnect the
negative wire from battery
terminal.

NOTE: Service air cleaner more
often when operating under
dusty conditions.

1. On the portable pump, unlatch

and open the pump top cover to

gain access to the air cleaner.

Disconnect negative battery cable.

2. Remove air cleaner cover

assembly by releasing the latches on

either side of the cover and lift cover

off pump.

NOTE: Before installing new
filter, lightly oil filter gasket with
fresh clean engine oil.

7. Oil the filter gasket and screw the

new oil filter on by hand until gasket

contacts filter adapter then tighten

an additional 1/4 to 1/2 turn.

8. Remove oil fill cap on valve cover

or oil dipstick and place on a clean

surface.

9. Using a funnel to prevent spills, refill

crankcase with the proper grade of

oil.

NOTE: The engine will require
a minimum of 3 pints (1.4 liters)
if the oil filter is not replaced
and 3.5 pints (1.6 liters) if the oil
filter is replaced.

10. Check oil level and replace

dipstick or oil fill cap.

11. Replace covers and remove

pump from work area.

12. Reconnect the negative battery

cable. Start pump and run for 30

seconds. Shut down the pump and

check oil level. Refill crankcase as

necessary.

Advertising