Warning

If any indication of the problem is found in the product, check to make sure

the product will operate as expected. Failure to do so can lead to serious ac-
cidents.

If any problem is found during using, setting or operating this product, use

the following table to confirm proper operation of the unit. If the opera-
tional problem is not found in the following table, contact the installation
personnel at the store where this product was purchased.

Condition

Possible Cause

Corrective Action

○ Does not operate.
○ Power is not sup-

plied.

○ DC Source LED of

the control unit
doesn't light.

○ Wiring of the power supply wire

is improper.

○ The fuse of the power supply

wire is blown out.

○ The locks of the solderless con-

nectors are not locked tightly.

○ Check wirings of +B, IGN,

GND as per instructions in
this manual.

○ Check wiring and replace

the fuse.

○ Check the lock of the solder-

less connectors.

○ DC Source LED of

the control unit is
blinking.

○ There is a wire short circuit or

disconnected wire somewhere.
Maybe there is something
wrong on gauge.

○ Reconfirm the wiring and

the gauge according to
operation manual. If any
defects are not found, please
ask the shop for inspection.

○ Warning LED on

gauge is blinking

○ There is a wire short circuit or

disconnected wire somewhere
on sensor or sensor wire. Maybe
there is something wrong be-
tween gauge and control unit.

○ Reconfirm the sensor and

sensor wire according to
operation manual. If any
defects are not found, please
ask the shop for inspection.

8 Troubleshooting

Condition

Possible Cause

Corrective Action

○ The illumination of

CR gauges is not
lighted. The illumi-
nation of BF gauges
is not darkened.

○ The ILM wiring is improper.
○ The locks of the solderless con-

nectors are not locked tightly.

○ The illumination of gauge is set

to off (illumination cancel).

○ The dimmer setting of ZD is

AUTO and vehicle is in bright
light.

○ Check wirings of ILM as per

instructions in this manual.

○ Check the lock of the solder-

less connectors.

○ Release illumination cancel

function as per instructions
in this manual.

○ Change the dimmer setting

to MANUAL or move vehicle
to a dark place.

○ Does not carry out

the ending mode.

○ The battery wiring is improper. ○ Check wiring of +B as per

instructions in this manual.

○ Check the solderless con-

nector of battery wiring.

○ Ask the store for inspection.

○ The needle pointer

is not around right

under 0 before

starting installation

with power off.

○ The needle pointer moved in

transit.

○ It is the unique feature of

stepping motor that the

needle pointer may move

when a slight impoct is

made to the gauge with

electricity off. Check if the

needle pointer goes back to

around 0 when the ignition

is turned from on to off. If

it does not, please contact

the store or our customer

service center.

72