■When the Defi-Link Display VSD CONCEPT is used WITHOUT a connection to the Defi-Link System

■When the Defi-Link Display VSD CONCEPT is used WITH a connection to the Defi-Link System

NOTE: If "MPH,

°

F, PSI" is selected in the

setting of units, data other than
the engine speed is not displayed.

NOTE: If "MPH,

°

F, PSI" is selected in the

setting of units, data other than
the engine speed is not displayed.

NOTE: When connected to the Defi-Link System, the PEAK button of the D.C.Unit is unavailable.

NOTE: When connected to the Defi-Link System, the PEAK button of the D.C.Unit is unavailable.

⑦Self-Diagnosis Function

⑥Warning Mode

When a current value exceeds the set value, the red LED and the name of the data blink. A buzzer sounds
at the same time if warning buzzer is turned on. One minute later, the red LED and the name of the data
stop blinking and start lighting and the current warning value is displayed. When several values exceed the
warning set values, the latest warning is indicated. Pressing the ENTER button will return to the last display
before the indication of warnings. If the value still exceeds the set value, the name of the data will continue
to blink.

I)If the auto warning mode is turned ON in the setting of auto warning

I)If the auto warning mode is turned ON in the setting of auto warning

When a current value exceeds the set value, the red LED and the name of the data blink. A buzzer sounds
at the same time if warning buzzer is turned on. One minute later, the red LED goes out, the buzzer is
stopped, and the name of the data blinks faster. The red LED lights up and a buzzer sounds again if the
warning data is selected to display in the digital display section by using the SELECT button. When several
values exceed the warning set values, the name of data which is being displayed in the digital display
section light up and other names blink.

Disconnection(open)
This display means that a wire disruption, disconnection or improper wiring
connection has occurred at the sensor or in the sensor wire.

Short circuit
This display means that a short circuit has occurred somewhere at the sensor or in
the sensor wire.

Serial error
This display means that communications between Defi-Link Display VSD CONCEPT
and the Defi-Link system have been interrupted.

Setting Error of number of cylinders
"x1000RPM" blinks if the number of cylinders of Defi-Link Control Unit II(or Defi-Link
Control Unit) is not set or if the METER OUTPUT2 connector of Defi-Link Control Unit
II and the LINK connector of D.C.Unit is connected by error.

NOTE: Even if REC button is pressed in vehicle's stopped condition, the vehicle speed data cannot be

recorded and Rec Mode will turn to Play Mode.

II)If the auto warning mode is turned OFF in the setting of auto warning

II)If the auto warning mode is turned OFF in the setting of auto warning

When current values exceed the values set as warnings by using Defi-Link Control Unit II(or Defi-Link Control
Unit) and when disconnection or short circuit of sensor wires or sensors are detected, the screen indicates the
warning.

※Priority is given to the tachometer warnings over other warnings.
※Warnings on boost and intake manifold pressure are not indicated.
※The warning on oil pressure is not indicated while the vehicle speed is under 10km/h(6MPH).

⑤Warning Set Mode

Pressing the WARN SET button of Defi-Link Control Unit II(or pressing the SELECT button of Defi-Link Control Unit)
will bring up Warning Set Mode. To set the warning value, please refer to the operations manual of Defi-Link Control
Unit II(or Defi-Link Control Unit).

NOTE: Once pause, fast-forward or rewind is performed with Defi-Link Control Unit II(or Defi-Link Control Unit), the

recorded speed data cannot be played back. To play back the speed data, Play Mode needs to be started
over again. Operation needs to be performed in vehicle's stopped condition. If the PLAY button is pressed
in vehicle's running condition, speed data will not be played back but Play Mode will turn to Rec Mode.

NOTE: The pulse free setting needs to be done again if units are changed.

NOTE: If the Defi-Link Display VSD CONCEPT is linked with the Defi-Link System, the setting of Defi-

Link Control Unit II(or Defi-Link Control Unit) is prioritized.

NOTE: This function operates when the Defi-Link Display VSD CONCEPT is linked with the Defi-Link

System and the temperature sensor is connected.

NOTE: This function operates when the Defi-Link Display VSD CONCEPT is linked with the Defi-Link

System and the temperature sensor is connected.

Oil Temp.

Engine Speed

※Examples of display

Boost

NOTE: If the Defi-Link Display VSD CONCEPT is linked with the Defi-Link System, the tachometer

warning2 cannot be set. The setting value of the tachometer warning of Defi-Link Control Unit
II(or Defi-Link Control Unit) is applied as a tachometer warning2. Please set up the tachometer
warning of Defi-Link Control Unit II(or Defi-Link Control Unit) higher than the tachometer
warning1 value. If the value is set lower than the warning1, the warning1 will be invalid.

NOTE: If the Defi-Link Display VSD CONCEPT is linked with the Defi-Link System, the warning buzzer

of Defi-Link Control Unit II cannot be absorbed.

NOTE: This function operates when the Defi-Link Display VSD CONCEPT is linked with the Defi-Link

System.

When the auto dimmer mode is on, the brightness of the display is adjusted automatically. Press
ENTER to Select one from three stages of brightness in the auto dimmer mode during the real mode or
the peak mode. When the manual dimmer mode is on, the brightness of the display can be set
manually at 5 stages in the real mode or the peak mode.