Caution, Chapter 11 – emergency operation – Snorkel AB46JE User Manual

Page 53

Advertising
background image

AB46JE – 0260072

49

If the main hydraulic system fails the aerial platform may

be lowered and stowed using the emergency power

system.

Emergency Power System

The emergency power system can be used to operate

the machine from the lower or upper controls.

A

Caution

The emergency power system is for emergency low-
ering and stowing only. The length of time the pump
can be operated depends on the capacity of the bat-
teries. Do not use this system for normal operation.

Only use the emergency power system if the main power

system fails.

Lower Controls

Use the following procedure to operate the machine using

the emergency power system from the lower controls.

1. Place the battery disconnect switch in the on position

(refer to Figure 11.1).

Figure 11.1 – Battery Disconnect Panel

2. Place the key in the start switch (refer to Figure 11.2)

and turn the start switch to the on position.

Figure 11.2 – Lower Controls

Battery Disconnect Switch

Battery Disconnect Switch

Emergency

Power Switch

Ground Operation

Switch

Emergency

Stop Button

Emergency

Power Switch

Ground Operation

Switch

Emergency

Stop Button

Control

Selector Switch

Start Switch

Control

Selector Switch

Start Switch

Chapter 11 – Emergency Operation

3. Pull the emergency stop button outward.

4. Place the controls switch in the lower control position.

5. Hold the ground operation switch in the on position

while holding the emergency power switch in the

emergency power position.

6. Hold the appropriate function toggle switch in the

desired direction.

Upper Controls

For the upper controls to be operational:

The battery disconnect switch must be in the on

position.

The start switch at the lower controls must be turned

on.

The emergency stop button at the lower controls must

be in the on position.

The control selector switch at the lower controls must

be in the platform position.

Use the following procedure to operate the machine using

the emergency power system from the upper controls.

1. Pull the emergency stop button outward (refer to

Figure 11.3).

Figure 11.3 – Upper Controls

2. Step down on the platform foot switch (refer to Figure

11.4).

Emergency

Power Switch

Emergency

Stop Button

Emergency

Power Switch

Emergency

Stop Button

Advertising