JLG G6-42A Service Manual User Manual

Page 226

Advertising
background image

Electrical System

9-62

G6-42A, G9-43A, G10-43A

9.16

JOYSTICK FAULT CODES
(G9-43A/G10-43A S/N 0160040675 AND AFTER INCLUDING 0160040468 & 016040672)

DTC

Event

Comment

Latched

211

Power Cycle

No motion restrictions

This Help Message is issued at each power-up.

This serves to indicate which messages have been
recorded in Logged Help since the last power-up
event.

No

2127

Aux Joystick Not In Neutral

Position At Power Up

Auxiliary Hydraulic A & B prevented

The auxiliary hydraulic joystick must be in the

neutral position (established by Calibration) when
the control system is energized or it is ignored until
is momentarily returns to neutral.

Active when AUX HYDRAULIC is ENABLED

No

2123

Joystick Trigger Switch

Active At Power Up

De-Clutch functionality prevented (transmission

always engaged)

The trigger for de-clutch should be open (released)

when the control system is energized or is ignored
until it momentarily opens.

No

2125

Joystick Roller Not In The

Neutral Position At Power

Up

Fork Tilt Up & Down prevented

The left roller must be in the neutral position

(established by Calibration) when the control
system is energized or it is ignored until is
momentarily returns to neutral.

No

2356

Auxiliary Hydraulic Joystick -
Neutral Disagreement

Auxiliary Hydraulic A & B prevented

The auxiliary joystick’s neutral switch was open

while the analog voltage was in the active range,
or the neutral switch was closed while the analog
voltage was in the neutral range. Auxiliary
hydraulics will be prevented until the next power
cycle. This fault may be caused by improper
joystick calibration, improper wiring, a joystick
issue or a control module issue.

Neutral switch must be open for 0%; closed

beyond ±25%

Yes

2357

Auxiliary Hydraulic Joystick -

Out Of Range High

Auxiliary Hydraulic A & B prevented

The auxiliary joystick analog voltage was

measured to be greater than 4.85V. Auxiliary
hydraulics will be prevented until the next power
cycle. This fault may be caused by improper
wiring, a joystick issue or a control module issue.

Active when Machine Setup’s AUX HYDRAULIC is

set to ENABLED

Yes

Advertising