JLG 600A_AJ Service Manual User Manual
Page 291
SECTION 6 - JLG CONTROL SYSTEM
3121201
– JLG Lift –
6-37
ENGINE SHUTDOWN:
7
0
1
DISABLED: No engine shutdown.
ENABLED: Shutdown engine when coolant temperature is greater than 110 deg. C or the
oil pressure is less than 8 PSI.
1
TILT:
8*
* Certain market selections
will limit tilt options and alter
default setting.
Note: Any of the selections
above will light the tilt lamp
when a tilted condition
occurs and will sound the
platform alarm when the
machine is also above ele-
vation.
1
2
3
4
5
5 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted
more than 5 degrees and above elevation; also reduces drive speed to creep.
4 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted
more than 4 degrees and above elevation; also reduces drive speed to creep.
3 DEGREES: Reduces the maximum speed of all boom functions to creep when tilted
more than 3 degrees and above elevation; also reduces drive speed to creep.
4 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when
tilted more than 4 degrees and above elevation; also disallows tower lift up, tower tele-
scope out, drive, main telescope out and main lift up.
3 DEGREES + CUT: Reduces the maximum speed of all boom functions to creep when
tilted more than 3 degrees and above elevation; also disallows tower lift up, tower tele-
scope out, drive, main telescope out and main lift up.
1
JIB:
9*
* Only visible under certain
model selections.
0
1
NO: No jib installed.
YES: Jib installed which has up and down movements only.
0
4 WHEEL STEER:
10*
* Only visible under certain
model selections.
0
1
NO: No four-wheel steer installed.
YES: Four-wheel steer installed.
0
SOFT TOUCH:
11*
* Only visible under certain
model selections.
0
1
NO: No soft touch system installed.
YES: Soft touch system installed.
0
GEN SET/WELDER:
12
0
1
NO: No generator installed.
BELT DRIVE: Belt driven setup.
0
Table 6-4. Machine Configuration Programming Information Software Version P5.3 to P6.1
Configuration Label/
Digit
Number
Description
Default
Number