4 daily walk-around inspection, 4 daily walk-around inspection -5 – JLG 15/20MSP Operator Manual User Manual
Page 23
SECTION 2 - PREPARATION AND INSPECTION
3121230
– JLG Lift –
2-5
2.4 DAILY WALK-AROUND INSPECTION
Begin the “Walk-Around Inspection” at item one (1) as noted on
the diagram. Continue around machine check each item in
sequence for the conditions listed in the following check list.
TO AVOID POSSIBLE INJURY, BE SURE MACHINE POWER IS “OFF”
DURING “WALK-AROUND INSPECTION”.
DO NOT OPERATE MACHINE UNTIL ALL MALFUNCTIONS HAVE BEEN
CORRECTED.
DO NOT OVERLOOK VISUAL INSPECTION OF THE BASE FRAME
UNDERSIDE. CHECK THIS AREA FOR OBJECTS OR DEBRIS WHICH
COULD CAUSE EXTENSIVE MACHINE DAMAGE.
INSPECTION NOTE: On all components, make sure there are no
loose or missing parts, that they are securely fastened, and that no
visible damage, leaks or excessive wear exists in addition to any
other criteria mentioned.
1. Drive and Caster Wheels - Check for any debris stuck
to or around wheels.
2. Base Frame - Check pot-hole-protection system com-
ponents; check for loose wires or cables dangling below
the base.
3. Manual Descent Control Valve - See inspection note
above.
4. Motor/Pump/Reservoir Unit - No evidence of hydraulic
leaks. Hydraulic oil level should be filled level with the
full line.
5. Batteries - Charge if necessary.
6. Platform Assembly and Gate - Quick-Change platform
mounting and mounting pins; platform railings; entry bar
or gate in proper working order; MSP - platform fasten-
ers.
7. Platform Control Console - Platform control; placards
secure and legible; emergency stop switch reset for
operation; Control markings legible.
8. Ground Control Station - Main Power Selector Switch
operable; placards secure and legible; emergency stop
switch operates properly.
9. Mast Assembly - Mast sections; slide pads; mast
chains; sequencing cables; platform control and power
cables (on side of mast); power cables properly ten-
sioned and seated in sheaves; cable sheaves rotating
freely.