SECTION 6 - JLG CONTROL SYSTEM
6-42
– JLG Lift –
3121623
Table 6-8. BATTERY CHARGER FAULT CODES
CODE
DESCRIPTION
STATUS
ACTION
8
Logic internal fault
The battery charger stops working
Call the assistance or change the
product.
13
Communication problem with
external memory
The battery charger stops working.
Call the assistance or change the
product.
19
Logic internal fault
The battery charger stops working.
Call the assistance or change the
product.
242
Error during the reading of the
micro controller internal
memory
The battery charger stops working.
Call the assistance or change the
product.
252
Short circuit in the battery
charger output.
The battery charger stops working
Turn the battery charger off and
eliminate the output short circuit. If
the problem persists call the
service or change the product.
246
Phase 1 finished for timeout
and not for natural reaching of
the control voltage.
The battery charger stops working
Control that the battery capacity is
compatible or control that the
battery conforms to the battery
charger purchased. If the battery is
correct and the problem persists
cal the service
241
Problem in CANBUS
communication with other
systems in the network
The managing may change according
to the different product firmware.
Control the correct functioning of
the CANBUS system
248
Too high temperature in the
battery charger
if the internal temperature exceeds 80°C
the battery charger reduces the power
to the 80% while it stops working if the
internal temperature exceeds 90°C. It
restarts at full power if the internal
temperature drops below 70°C
249
Battery temperature too high.
The battery charger stops working if the
temperature exceeds 55°C or drops
below -20°C. When the battery
temperature drops under 45°C or rises
over -10°C the battery charger restarts
working
251
A network hole has been found
The battery charger stops the supply. It
restarts once the alarm conditions
disappear.
If the problem persists control
supply of the battery charger
network.
18
Stalling or very long network
hole.
The battery charger stops the supply. It
restarts once the alarm conditions
disappear or after restarting.
If it is a network hole control the
network supply of the battery
charger.
245
Irregular current absorption
The battery charger stops the supply. It
restarts once the alarm conditions
disappear.
If the problem persists call the
service or change the product.